![strapex STB 71 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/strapex/stb-71/stb-71_operating-instructions-manual_1383445014.webp)
14
of 28
V 03.17
STRAPEX STB 71/73/75
ENGLISH
4.3
Setting strap tension
The set tension force is displayed continuously when the tool is ready for operation.
►
Press "Tension force" button (2).
–
The set tension force flashes for 5 sec
-
onds.
– The + (1) and – (3) buttons appear.
– Unused displays disappear.
►
Press the + (1) or – (3) button until the desired
tension force is displayed.
– The status indicator bar (4) shows the set
tension force in relation to the possible
maximum value.
►
Save: Press the "Tension force" button (2) or
wait for 5 seconds.
● Switch between display in "N" or "lbf": Press the flashing "Tension force" button (2) for
two seconds.
● Every time the button is pressed an acoustic signal confirms the action.
●
The tension force is displayed continuously when the tool is operational.
●
Setting soft tension (Section 4.4).
STB 71:
1
2
3
4
5
6
7
8
9
Standard:
N*
400
500
600
700
800
900
1000
1100
1200
lbf*
90
110
135
155
180
200
225
250
270
Soft
N
150
225
300
375
450
525
600
675
750
lbf
33
50
67
85
100
120
135
150
165
STB 73:
1
2
3
4
5
6
7
8
9
Standard:
N*
900
1100
1300
1500
1700
1900
2100
2300
2500
lbf*
200
250
290
340
380
430
470
520
560
Soft
N
400
520
640
760
880
1000
1120
1240
1360
lbf
90
115
145
170
200
225
250
280
305
STB 75:
1
2
3
4
5
6
7
8
9
Standard:
N*
1300
1700
2100
2500
2900
3300
3700
4100
4500
lbf*
290
380
470
560
650
740
830
920
1000
Soft
N
400
550
700
850
1000
1150
1300
1450
1600
lbf
90
120
160
190
225
260
290
325
360
(rounded values)
* N = Newton, lbf = pound-force per square inch
4
1
2
3