Multisport
Pro Range
ZI de Bel Air 44850 LE CELLIER FRANCE [email protected] Tél. +33 (0)2 40 25 46 90
IA452MB7120-2_D - Installation 452MB7120-2.docx
Page 7
S
YBJ30
K
K
P
100-240V
50/60Hz
SC24
SC24
1
2
3
4
YBJ30
T
2
4
1
3
T
Q
S
K
P
100-240V
50/60Hz
S
K
P
100-240V
50/60Hz
K
K
SC24
Cable transmission model - Electrical installation
Caution: the scoreboard must not be connected to mains before installation has been fully completed.
Control cable and wall junction box
The transmission cable supplied is a telephone cable: type 2 pairs 6/10
ths
.
Mount the wall junction box YBJ30 onto the wall close to the scoring table.
Connect the control cable (Q) on the connector (T) of the scoreboard making sure that the colour code is followed (Please note –
RS485: Rx+ and Rx- must be connected on a twisted pair).
Fix the control cable into place making sure that it does not run along side the 100-240V mains cables.
Connect the end wires into the junction box YBJ30, making sure that the colour code is followed. If several units are connected
together, their cables must be wired in parallel in the wall junction box.
Modules M2, M3 and M4: mains cable (P)
Caution: only use the power cable provided. This cable is equipped with pre-wired plug; the wiring should not be modified.
Two cable ports (K) are available for the mains cable: one in the profile of the module another one at the back.
Remove the grommet of the module, take the connector (S) out and connect the mains cable.
Put the connector (S) inside the module and put the grommet back into place.
Run and fix the mains cable (P) and connect it to 100-240V via a bipolar 4A circuit breaker (not supplied). Bipolar circuit breaker must
be easy to reach.
Control cable (Q): (1) = GND = blue wire / (2) = Rx+ = white wire / (3) = Rx- = grey wire / (4) = +24V = transparent wire
End of the installation
Slide back and screw in each of the corner plastic shields.
Connect the scoreboard to mains.
Try out the scoreboard operating functions (see operating functions).