Page 4

 

42

42

610

1960

610

1860

300

20

20

20

20

F

F

F

F

F

F

F

F

F

F

F

F

R

R

R

300

300

K

Z

Z

K Z

Z

F

F

F

F

1110

20

44

806

20

Z

Z

K

K Z

K

K Z

 

 

Before installation  

In no circumstances does installation require the scoreboard casing to be opened. 

The electronic elements controlling the luminous display are mounted on extractable racks (R). In order to be able to carry out any 
maintenance, a clear space of at least 30 cm is necessary for the extraction of the racks. Attention: installation must be performed by 
qualified staff. 

Modules M2, M3 and M4: the mains cable can be taken out through the profile or at the back of the module (points K). In this last case, the 
mains cable must be connected in the module before being fixed (see chapter "Electrical installation" – "Mains cable").  

 

Draw the position of the mounting points (F) onto the wall or onto the support frame following the measures of the diagram. 

Put plugs or inserts for Ø 8 mm screws. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions in mm 

 

 (Z): Holes for mounting or disassembling the front face in some maintenance cases.  

    

 

 

Содержание 452 MB 7120-2

Страница 1: ...ZI de Bel Air 44850 LE CELLIER FRANCE stramatel stramatel com T l 33 0 2 40 25 46 90 IA452MB7120 2_D Installation 452MB7120 2 docx Page 1 TECHNICAL DATA INSTALLATION INSTRUCTIONS Model 452 MB 7120 2...

Страница 2: ...Multisport Pro Range ZI de Bel Air 44850 LE CELLIER FRANCE stramatel stramatel com T l 33 0 2 40 25 46 90 IA452MB7120 2_D Installation 452MB7120 2 docx Page 2 NOTES...

Страница 3: ...s of its sound However it is possible to dampen down the sound by replacing the grill in front of the horn by a full plate of the same dimension 180x160mm Main control console Radio controlled model D...

Страница 4: ...In order to be able to carry out any maintenance a clear space of at least 30 cm is necessary for the extraction of the racks Attention installation must be performed by qualified staff Modules M2 M3...

Страница 5: ...reboard Take the connectors Y out of the modules Put the module M1 into place on the wall or on the support frame and screw in 8 mm screws Module M2 Mains cable port remove one of the grommets K of th...

Страница 6: ...at the back Remove the grommet of the module take the connector S out and connect the mains cable Put the connector S inside the module and put the grommet back into place Run and fix the mains cable...

Страница 7: ...e the 100 240V mains cables Connect the end wires into the junction box YBJ30 making sure that the colour code is followed If several units are connected together their cables must be wired in paralle...

Страница 8: ...ZI de Bel Air 44850 LE CELLIER FRANCE 33 0 2 40 25 46 90 Fax 33 0 2 40 25 30 63 stramatel stramatel com www stramatel com...

Отзывы: