WARNING:
This appliance must be earthed.
• This appliance must be fitted to a switch providing all pole disconnection with a minimum contact
separation of 3mm.
•
Access to the mains terminal is gained by removing the terminal block cover at the rear of the
appliance.
• Connection should be made with a suitable flexible cable with a minimum temperature rating of
70°C.
•
First strip the wires then push the cable through the cable clamp.
•
Connect the cable to the terminal block and tighten the cable clamp screws - see diagram.
• Refit the terminal box cover.
• Sufficient cable should be used to allow the cooker to be pulled out, but must hang clear of the floor
so it does not become twisted or trapped when the cooker is pushed back.
The terminal block screws and clamps can be damaged by excessive tightening and untightening. DO
NOT USE POWER TOOLS!
Single Phase Connection (230V ~ 50Hz)
4
5
2
3
6
1
N
L
Shorting
Links
Shorting
Link
Connect cable to terminal block:
L to terminal 2.
N to terminal 5.
Earth to terminal.
Ensure shorting links are fitted between
terminals 1-2, 2-3, 4-5 and 5-6.
Ensure all screws are fully tightened.
Cable
Clamp
Three Phase Connection (230/400V 3N ~ 50Hz)
4
5
2
3
6
1
N
Shorting
Links
Connect cable to terminal block:
Remove shorting links 1-2 and 2-3
L1, L2 and L3 to terminals 1, 2 and 3.
N to terminal 5.
Earth to terminal.
Ensure shorting links are fitted between
terminals 4-5 and 5-6.
Ensure all screws are fully tightened.
Cable
Clamp
L1 L2 L3
CONNECT TO THE ELECTRICITY SUPPLY - TERMINAL BLOCK
Содержание ST RICH DX S1000DF
Страница 1: ...USER GUIDE A commitment to Stoves Range DF GTG Part Number 083769902...
Страница 72: ...Please keep this handbook for future reference or for anyone else who may use the appliance...
Страница 73: ...Please keep this handbook for future reference or for anyone else who may use the appliance...
Страница 74: ...Please keep this handbook for future reference or for anyone else who may use the appliance...
Страница 80: ......
Страница 81: ......