C O N N E C T T O T H E G A S S U P P LY
The inlet to the cooker is ½” BSP internal situated at
the rear right corner. Fit the bayonet connection. This
should be located so as to ensure that the flexible
connector hose does not kink.
6
Under no circumstances should the
flexible connector be allowed to come
into contact with the vertical oven flue
tubes on the rear of the appliance.
Use a 900 mm - 1125 mm length of flexible connector.
Ensure that all pipework is of the correct rating for
both size and temperature.
Flexible connections should comply with the relevant
national regulations and codes of practice in force in
the country where it is intended to be installed. Parts
of the appliance likely to come into contact with a
flexible connector have a temperature rise of less than
70 °C.
After installation, make sure all connections are gas
sound.