INSTALLATION INSTRUCTIONS
Step 3: Connect to gas supply
1. The inlet to the appliance is
1
⁄
2
” BSP
situated towards the top right
corner of the rear.
2. Fit the bayonet connection to the
wall in the shaded area as shown.
The shaded area shown is
applicable to installations in
minimum depth cabinets.
If more room is available, the
bayonet fixing area can be
extended, provided that the
flexible tube does not obscure the
fan intake.
3. Use a 900 mm - 1125 mm length
of flexible connector. The flexible
connector shall be fitted such that
it cannot come into contact with a
moveable part of the housing unit
(eg; drawer) and does not pass
through any space susceptible of
becoming congested. Make sure
that the flexible connector does not
block the cooling fan inlet.
4. Flexible connections should be to
BS 669. Parts of the appliance
likely to come into contact with
a flexible connecter have a
temperature rise less than 70˚C.
5. Rigid connections must be accessible
to disconnect for servicing. Cut a
150 mm square hole in the right
hand rear corner of the support
shelf for the supply pipe.
6.
Make sure all connections
are gas sound.
31
Rear
Wall
60 mm
60
mm
60 mm
square
23894 02 - Q901G/900G RS2 03/04/2001 14:19 Page 33
Содержание 900G
Страница 2: ...23894 02 Q901G 900G RS2 03 04 2001 14 19 Page 2 ...
Страница 43: ...NOTES 41 23894 02 Q901G 900G RS2 03 04 2001 14 19 Page 43 ...
Страница 44: ...NOTES 42 23894 02 Q901G 900G RS2 03 04 2001 14 19 Page 44 ...
Страница 45: ...NOTES 43 23894 02 Q901G 900G RS2 03 04 2001 14 19 Page 45 ...
Страница 47: ...23894 02 Q901G 900G RS2 03 04 2001 14 19 Page 47 ...
Страница 48: ...08 23894 02 2000 RS2 23894 02 Q901G 900G RS2 03 04 2001 14 19 Page 48 ...