INSTALLATION INSTRUCTIONS
Before you start
:
Please read the instructions, planing your
installation will save you time and effort.
Check that your appliance is suitable for
the gas supply in your house - ie; Natural
Gas only. This is clearly marked on the
data badge.
The appliance must be installed (and
serviced) by a Corgi registered approved
installer or a person competent to ensure
that the installation is in accordance with
“The Gas Safety (Installation & Use)
Regulations 1994”, & the “The Gas
Safety (Installation & Use) (Amendment)
Regulations 1996”. Failure to comply with
these Regulations is a criminal offence.
Where regulations or standards have been
revised since this handbook was printed,
always use the latest edition.
In the UK the regulations and
standards are as follows:
1. Gas Safety Regulations 1996
(Installation and Use).
2. Building Regulations - Issued by the
Department of the Environment.
3. Building Standards (Scotland)
(Consolidated) - Issued by the Scottish
Development Department.
4. The current I.E.E. Wiring Regulations.
5. Electricity at Work Regulations 1989.
6. BS 6172 Installation of Domestic Gas
cooking Appliances
7. Installation & Servicing Instructions for
this appliance.
Ventilation Requirements
The room containing the appliance should
have an air supply in accordance with
BS 5440: Part 2: 1989:
•
All rooms require an openable window,
or equivalent, and some rooms will
require a permanent vent as well.
•
For room volumes up to 5 m
3
an air
vent of 100 cm
2
is required.
•
If the room has a door that opens
directly to the outside, or the room
exceeds 10 m
3
NO AIR VENT is
required.
•
For room volumes between 5 m
3
and
10 m
3
an air vent of 50 cm
2
is
required.
•
If there are other fuel burning
appliances in the same room, BS
5440: Part 2: 1989 should be
consulted to determine the air vent
requirements.
•
This appliance must not be installed in
a bed sitting room of less than 20 m
3
or in a bathroom or shower room.
Windows and permanent vents should
therefore not be blocked or removed without
first consulting a CORGI gas installer.
Failure to install appliances correctly
is dangerous and could lead to
prosecution.
27
23894 02 - Q901G/900G RS2 03/04/2001 14:19 Page 29
Содержание 900G
Страница 2: ...23894 02 Q901G 900G RS2 03 04 2001 14 19 Page 2 ...
Страница 43: ...NOTES 41 23894 02 Q901G 900G RS2 03 04 2001 14 19 Page 43 ...
Страница 44: ...NOTES 42 23894 02 Q901G 900G RS2 03 04 2001 14 19 Page 44 ...
Страница 45: ...NOTES 43 23894 02 Q901G 900G RS2 03 04 2001 14 19 Page 45 ...
Страница 47: ...23894 02 Q901G 900G RS2 03 04 2001 14 19 Page 47 ...
Страница 48: ...08 23894 02 2000 RS2 23894 02 Q901G 900G RS2 03 04 2001 14 19 Page 48 ...