Method 2: Extraction through
an outside wall
The fan draws cooking fumes through
the washable grease filter into the
underside of the hood, then the fumes
are expelled through a duct or directly
through an outside wall.
Refer to figures 5 & 6.
Assembly
1. Remove the grease filters.
2. Remove the carbon filters (if
supplied) and discard, as this is
not required when installing the
cooker hood as an extractor fan.
3. Secure the connection flange.
4. Using a 120 mm internal diameter
link pipe, attach connection flange
to the outside vent.
5. Insert the upper link section inside
the lower link section with the slots
turned downwards.
6. Secure the lower link section to the
hood using the screws provided.
7. Move the upper link section down
as far as the wall brackets and
secure with the screws provided.
Wall vent kit and ducting
•
For connecting the hood outlet
adaptor to the outside wall, we
recommend that a wall vent kit is
purchased from your supplier or
local hardware store.
•
Use a 125 mm diameter ducting
kit and connect to the ducting
outlet adaptor.
•
Horizontal duct runs should be
avoided. A slope of 5˚ or more
upwards from the hood to the wall
outlet will assist the flow of air.
•
The ducting pipe and any connecting
pieces should be coupled to the
preceding piece by pushing into
and never over it - the upper part
must be fitted over the lower part.
•
The outlet from the hood must not
be ducted into a wall cavity,
through a ventilator shaft or
through a chimney. It must not be
ducted through a flue used by a
non-electrically powered appliance.
•
Adequate ventilation must be
provided if a cooker hood extracts
fumes from the room at the same
time as an appliance powered by
a fuel other than electricity (such
as a gas appliance) is operated.
The extractor hood removes air
from the room which the burner is
dependant on for combustion.
10
Installation
Содержание 1000DCP
Страница 1: ...S1100 Professional Cooker Hood User Installation Instructions ...
Страница 2: ......
Страница 16: ...STONEY LANE PRESCOT MERSEYSIDE L35 2XW 08 27234 01 09 2011 3LIK1005 ...