Health and Safety Precautions 

Special care must be taken when installing the stove such that the requirements of the Health and Safety 
at Work Act are met. 
 

Handling  

This appliance is very heavy. Adequate facilities must be available for loading, unloading and site handling. 
 

Fire Cement  

Some types of fire cement are caustic and should not be allowed to come into contact with the skin. In case 
of contact, wash immediately with plenty of water. 
 

Asbestos 

This stove contains no asbestos. If there is a possibility of disturbing any asbestos in the course of installation, 
then please seek specialist guidance and use appropriate protective equipment. 
 

Metal Parts 

When installing or servicing this stove, care should be taken to avoid the possibility of personal injury. 
 

Installation Instructions 

Please Check The Following: 

Any existing chimney/flue system must be confirmed as suitable for this appliance as defined in Building Regulations Document J. 
It must be swept and inspected, by a competent person (see notes), to confirm that is structurally sound and free from cracks and 
obstructions. The diameter of the Flue should not be less than Ø125mm and not more than Ø230mm. Do not connect to systems 
that have large voids or spaces. If any of these requirements are not met, the chimney should be lined by a suitable method. If the 
chimney is suspected of previously serving an open fire it must be swept again, within a month of regular use, to clear any soot that 
may have been dislodged due to the variation in combustion levels and higher flue gas temperature levels. The chimney/flue 
system exit must comply with Building 
Regulations Document J. The minimum height and should terminate in accordance with Table 1. 
 
FLUE OUTLET POSITIONS (DOCUMENT J): 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Содержание HAMER HD5

Страница 1: ...ve the stove ready for operation and instruct the user in the correct use of the appliance and operation of controls The installer must fill out the Installation and commissioning check list Hamer Sto...

Страница 2: ...kg Recommended Fuels Wood Seasoned Wood less than 20 moisture content Log Length 300mm FUELS Mean Flue Gas Temperature 291 Flue Gas Mass Flow 3 9 Flue Outlet Size 125mm VENTILATION Where leakage is gr...

Страница 3: ...ECO HD5 ECO HD5 Singleton ECO HD5 Poulton ECO HD5 Hambleton...

Страница 4: ...Dimensions...

Страница 5: ...a chimney that serves any other heating appliance Extractor Fans Extractor Fans and or Cooker Hoods must not be installed in the same space or room as this can cause the appliance to emit fumes into...

Страница 6: ...llation Instructions Please Check The Following Any existing chimney flue system must be confirmed as suitable for this appliance as defined in Building Regulations Document J It must be swept and ins...

Страница 7: ...properties Clearances Safety distances to combustible materials Side 750mm Rear 750mm In addition it is strongly recommended that any furniture or other combustible materials are kept at least 900mm c...

Страница 8: ...um 2 5mm water gauge 12 to 25 Pascals is required for satisfactory appliance performance When this is measured at the draught reading point at the back right hand side of the stove it equates to 12 Pa...

Страница 9: ...d on top of this Light the newspaper and close the door NEVER USE FLAMMABLE LIQUIDS 3 Allow the fire to burn until all the pieces of wood are alight and burning More and larger pieces of wood can now...

Страница 10: ...lass after a fire to prevent any build up of deposits This is best done using a stove glass cleaner with a cloth or paper towel Types of fuel Mineral Fuel Authorised fuels can be used in smoke control...

Страница 11: ...le right across the solid fuel industry including trade associations organisations and suppliers and beyond The government department DEFRA specifically referenced Burnright in its Clean Air Strategy...

Страница 12: ...pt and passed the soundness test Has this appliance passed the flue draught test Please write down the flue draught reading Has this appliance passed the smoke test Have you explained what fuels can b...

Страница 13: ...Replaced Recommendations Contact number Signature 3rd Service Date of Service Servicing Company Engineer Any Parts Replaced Recommendations Contact number Signature 4th Service Date of Service Servici...

Страница 14: ...Recommendations Contact number Signature 8th Service Date of Service Servicing Company Engineer Any Parts Replaced Recommendations Contact number Signature 9th Service Date of Service Servicing Compa...

Страница 15: ...to be recorded This is needed in the event of a claim during the warranty period 4 Only genuine Stove Industry Supplies spare parts or consumables can be used in the servicing and maintenance of the...

Страница 16: ...al and re installation of an appliance subject to a warranty claim Stove Industry Supplies total liability will only extend to the total purchase price paid for the goods in any warranty claim Stove I...

Страница 17: ......

Страница 18: ...Stove Industry Supplies Ltd 103 105 Mowbray Drive Blackpool Lancashire FY3 7UN Tel 01253 397200 Email sales stoveindustrysupplies com Web www stoveindustrysupplies com...

Отзывы: