General Guidance 

It is important that your stove is correctly installed and operated as Stove Industry Supplies cannot accept responsibility for any 
fault arising through incorrect installation, use, maintenance or servicing. 
 
These instructions cover the basic principles to ensure satisfactory installation of the stove, although detail may need slight 
modification to suit particular local site conditions. 
 
This is a Domestic Appliance and must only be used in accordance with these instructions. Do not place articles that are affected 
by high temperatures on, or near, this appliance. Do not place furniture or other items within 1 metre of the front of this appliance. 
 

Building Regulations 

The installation must comply with current local regulations including Building Regulations, Local Authority Byelaws and other 
specifications or regulations including UK or EU standards referred to as they affect the installation of the stove. Approved 
Document J is particularly important for England and Wales and can be downloaded for no cost at: 

http://www.planningportal.gov.uk/england/professionals/en/4000000000503.html

  

 
The Building Regulations requirements may also be met by adopting the relevant recommendations in the current issues of British 
Standards BS 8303 and BS EN 15287-1. 
 

Fuels 

Only use recommended fuels which are seasoned (or kiln dried) wood logs or smokeless briquetted fuels. The appliance can be 
damaged by burning petroleum coke, liquid fuels or general rubbish and this will invalidate your warranty and risk your personal 
safety. 

The appliance must not be used as a rubbish incinerator.

  

Helpful links to find fuel suppliers: 
Hetas:   

 

 

 

 

 

 

www.hetas.com

  

Woodsure:  

 

 

 

 

 

 

www.woodsure.co.uk

 

Solid Fuel Association: 

 

 

 

 

 

 

www.solidfuel.co.uk

  

 

Chimney Warning 

This stove must not be installed into a chimney that serves any other heating appliance. 
 

Extractor Fans 

Extractor Fans and/or Cooker Hoods must not be installed in the same space or room as this can cause the appliance to emit 
fumes into the room, 

If unavoidable the appliance must be checked with A.D. 1.21 and necessary action taken. 

 
Ventilation  

Adequate ventilation is ESSENTIAL for the safe and efficient operation of any solid fuel or wood burning appliance. Ventilation 
MUST be provided where required by the stove output or flue under-performance. Keep all ventilation clear and free of blockage. 
 

Competent Person Scheme 

Stove Industry Supplies recommend that this stove is installed by a member of an accredited competent persons scheme. HETAS 
Ltd operate such a Scheme and a listing of their Registered Competent Persons can be found on their website at 

www.hetas.co.uk

  

 
If the installer is not a member of a competent 

person’s scheme, it is a legal requirement, in the UK, to notify your Local Building 

Control Officer in advance of any installation work starting. 
 

Cleaning and Chimney Sweeping 

It’s important to have your chimney swept at least twice a year when burning wood and at least once a year when burning 
smokeless fuels.  The best times to have your chimney swept are just before the start of the heating season and after your stove 
has not been used over a prolonged period. If sweeping twice a year, the second time should be after the peak of the main heating 
season. Always use a registered member of an accredited association:  
 
HETAS:   

 

 

 

 

 

 

www.hetas.co.uk

  

Guild Of Master Chimney Sweeps:   

 

 

 

www.guildofmasterchimneysweeps.co.uk

  

National Association of chimney sweeps: 

 

 

 

www.nacs.org.uk

 

Association of Professional Independent Chimney Sweeps: 

 

www.apics.org.uk

  

Sweep Safe: 

 

 

 

 

 

 

www.sweepsafe.com

 

Institute Of Chimney Sweeps: 

 

 

 

 

www.icsweeps.com

 

The Chimney Sweep Academy: 

 

 

 

 

www.chimneysweepacademy.org

  

The National Chimney Sweeping Safety Association:   

 

www.ncssa.co.uk

  

Northern Ireland Association of Chimney Sweeps: 

 

 

www.niacs.co.uk

  

 
 
 
 
 
 
 

Содержание HAMER HD5

Страница 1: ...ve the stove ready for operation and instruct the user in the correct use of the appliance and operation of controls The installer must fill out the Installation and commissioning check list Hamer Sto...

Страница 2: ...kg Recommended Fuels Wood Seasoned Wood less than 20 moisture content Log Length 300mm FUELS Mean Flue Gas Temperature 291 Flue Gas Mass Flow 3 9 Flue Outlet Size 125mm VENTILATION Where leakage is gr...

Страница 3: ...ECO HD5 ECO HD5 Singleton ECO HD5 Poulton ECO HD5 Hambleton...

Страница 4: ...Dimensions...

Страница 5: ...a chimney that serves any other heating appliance Extractor Fans Extractor Fans and or Cooker Hoods must not be installed in the same space or room as this can cause the appliance to emit fumes into...

Страница 6: ...llation Instructions Please Check The Following Any existing chimney flue system must be confirmed as suitable for this appliance as defined in Building Regulations Document J It must be swept and ins...

Страница 7: ...properties Clearances Safety distances to combustible materials Side 750mm Rear 750mm In addition it is strongly recommended that any furniture or other combustible materials are kept at least 900mm c...

Страница 8: ...um 2 5mm water gauge 12 to 25 Pascals is required for satisfactory appliance performance When this is measured at the draught reading point at the back right hand side of the stove it equates to 12 Pa...

Страница 9: ...d on top of this Light the newspaper and close the door NEVER USE FLAMMABLE LIQUIDS 3 Allow the fire to burn until all the pieces of wood are alight and burning More and larger pieces of wood can now...

Страница 10: ...lass after a fire to prevent any build up of deposits This is best done using a stove glass cleaner with a cloth or paper towel Types of fuel Mineral Fuel Authorised fuels can be used in smoke control...

Страница 11: ...le right across the solid fuel industry including trade associations organisations and suppliers and beyond The government department DEFRA specifically referenced Burnright in its Clean Air Strategy...

Страница 12: ...pt and passed the soundness test Has this appliance passed the flue draught test Please write down the flue draught reading Has this appliance passed the smoke test Have you explained what fuels can b...

Страница 13: ...Replaced Recommendations Contact number Signature 3rd Service Date of Service Servicing Company Engineer Any Parts Replaced Recommendations Contact number Signature 4th Service Date of Service Servici...

Страница 14: ...Recommendations Contact number Signature 8th Service Date of Service Servicing Company Engineer Any Parts Replaced Recommendations Contact number Signature 9th Service Date of Service Servicing Compa...

Страница 15: ...to be recorded This is needed in the event of a claim during the warranty period 4 Only genuine Stove Industry Supplies spare parts or consumables can be used in the servicing and maintenance of the...

Страница 16: ...al and re installation of an appliance subject to a warranty claim Stove Industry Supplies total liability will only extend to the total purchase price paid for the goods in any warranty claim Stove I...

Страница 17: ......

Страница 18: ...Stove Industry Supplies Ltd 103 105 Mowbray Drive Blackpool Lancashire FY3 7UN Tel 01253 397200 Email sales stoveindustrysupplies com Web www stoveindustrysupplies com...

Отзывы: