THE ADVANCED SETINGS
Turn off counter:
The Stove Guard has added a counter cycle that will record each time the unit turns the stove off. This feature is important
for managed-care type situations to monitor the users use, to determine how many times they forgot about their electric
stove.
If Stove Guard is in the STOVE-OFF mode holding the STOVE-OFF and LEFT TIME buttons, will show number of times
the Stove Guard shut off the stove in auto and/or timer mode as selected. Numbers shown are from
00.
to
99.
or
Ab.
"Ab." means that Stove Guard turned the stove off more than (Above) 99 times. Holding the STOVE-OFF button will reset
counter to
00.
After 8 seconds time-out display goes back to blank.
Custom settings:
If Stove Guard is in the STOVE-OFF mode, holding the STOVE-OFF, and RIGHT TIME buttons will start the setting
mode. Display will show two numbers followed with decimal points. It represents the current settings. User can adjust
settings with holding left and/or right time button. Press on the left time button, add 1 to left digit setting. Press on the right
time button, add 1 to right digit setting. After reaching the maximum both setting digits go to 0. Pressing the STOVE-OFF
button will save the new settings (accepted - display shows
AC
). If a time-out occurs without holding the STOVE-OFF
button display will show
nA
- not accepted, and the old settings remain.
Left digit meaning:
Start calculation with 0.
Auto On & current detection - choose one:
Goes to AUTO from SG-OFF mode after 1 hour without current
- Add 0 (nothing)
Don’t go automatically to AUTO (Auto On disabled)
- Add 3
Current detection disabled (assume always current)
- Add 6
Disabling the current detection is not recommended. Turn this setting on only if current detection doesn’t work.
Stove Guard model - choose one:
Standard
- Add 0
Delay
- Add 1
Password
- Add 2
Possible left digit settings:
0.
÷
8.
Right digit meaning:
Start calculation with 0.
Red SG-OFF LED meaning - choose one:
Lights when Stove Guard is in the SG-OFF mode
- Add 0
Lights when current is detected
- Add 7
Output connector and buzzer setting - choose one:
No buzzing and no pulse on output connector
- Add 0
Just in auto mode with 0.8 s pulse
- Add 1
Just in auto mode with 2 s pulse
- Add 2
Just in auto mode two 1 s pulse repeating
- Add 3
In auto and timer mode with 0.8 s pulse
- Add 4
In auto and timer mode with 2 s pulse
- Add 5
In auto and timer mode two 1 s pulse repeating
- Add 6
If “No buzzing and no pulse on output connector” is selected counter which records how many times the unit turns the
stove off is disabled.
Repeating means two 1 second closed contact pulse with 0.6 s open contact between (buzzer - two short beeps). This is
repeating every minute until user turn the stove on again (press button or re-enter motion detection area depending of the
stove guard mode).
For a pulse triggered devices as a phone dialer 0.8s pulse is recommended. For a buzzer 2s pulse or repeating mode is
recommended.
Possible settings: 0. ÷ 13. Display shows:
0.
÷
d.
Digits greater than 9 are shown as:
10 "A"
12 "C"
11 "11"
13 "d"
Setting example:
User want to set that Red SG-OFF LED lights when Stove Guard is in the SG-OFF mode and gives 2 seconds audible
signal (and relay pulse) when Stove Guard turn off the stove in Auto and Timer mode.
Right digit = 0
[start]
+ 0
[LED setting]
+ 5
[buzzer/relay setting]
= 5.