[3] STOVE OFF button

When pressed turns the stove off (STOVE-OFF mode).

Holding for DELAY model.

[4] TIMER button

Turns the Stove Guard in TIMER mode and resets preset time.

Holding for DELAY model.

[5] And [6] TIME buttons

TIME buttons are used for adjusting the preset time for AUTO and TIMER mode. Pressing TIME buttons changes the
preset time.

User had to hold time buttons to start changing the preset time for DELAY model.

User can choose between

01

and

15

minutes in AUTO and

01

minutes and

7.0

hours in TIMER mode. Left button adds

10 minutes or 1 hour and the right button adds 1 minutes or 0.1 hour (6 minutes) to the preset time. After reaching the
maximum setting the preset time goes back to

01

minute.

For the safety reason, after a power failure, if power goes off and return back, the Stove Guard will "wake-up" in AUTO
mode with stove shut off. Display shows

PO

. The infrared sensor will not reset clock to preset time until user press any

button. If mode before power failure was Stove Off, the Stove Guard will remain in this mode.

When Stove Guard is in SG-OFF mode, one hour after the Stove Guard does not detect current (stove is turned off),
Stove Guard will automatically go to AUTO mode. This option can be disabled. If Stove Guard is in the STOVE-OFF
mode, the Stove Guard will not go to AUTO mode automatically, regardless of Auto On settings.

The output connector and buzzer in the Stove Guard monitor unit make a change from open contact to closed (start
buzzing) and goes back to open contact (stop buzzing) every time when Stove Guard turns the stove off if this option is
selected.

For PASSWORD model only:

The Password model version features password locking, for managed-care type situations. Administrators can set the
device to the User’s particular needs, and then password lock it. If buttons are locked only the unlock function is enabled.

To lock/unlock Stove Guard's buttons:

While holding SG-OFF button, press and hold RIGHT TIME button for 3

seconds. Display will show

L..

for lock or

U..

for unlock function depend of previous lock/unlock state. User has 25

seconds to enter each of four digits [1] to [6] (button SG-OFF till right TIME) password for (un)locking. While user enters
the password, display will show "L" or "U" lock/unlock, and ".." or 1 to 3 dashes - represents the numbers of password
digits entered. If password is correct display will show

LL

and all pushbuttons are locked or

UU

and pushbuttons are

unlocked. If password is not correct display will show

LF

- lock fail or

UF

- unlock fail. In case of 25 seconds time-out

lock/unlock also fails.

To change the password:

While holding SG-OFF button, press and hold the left TIME button for 3 seconds. Display will

show

d..

. User has to enter four digits [1] to [6] of current password. Display will show

d..

,

d_

,

d=

,

and

d

during

entering digits of old password. Display will change to

P..

and user can enter a new password. After entering the new

password display will show

C..

, and user have to enter the new password again for confirmation. If old password is

correct and the same new password is entered twice display will show

CC

and the new password is accepted. Otherwise

display will show

CF

- confirmation fails - and old password will remain valid.

THE RELAY OUTPUT AND THE BUZZER

The output connector is located on back of electronic monitor unit (EMU) near white cable connector. It can be used to
trigger an external monitoring device, whenever the Stove Guard disables the stove; such as a Phone Dialer or Alarm
system. The buzzer in Stove Guard monitor unit make a audible signal at same time as the relay output make change
from open contact to closed (start buzzing) and goes back to open contact (stop buzzing).

Содержание Guardian COOKTOP

Страница 1: ...last setting STOVE GUARD also can be used in a TIMER mode to set a maximum cooking time after which the stove will be automatically turned OFF IMPORTANT WARNING Installation of the STOVE GUARD COOKTOP Model requires a licensed Electrician to be wired properly according to local electrical codes Do not disassemble any of the components There are no user serviceable parts inside Refer servicing to a...

Страница 2: ...utton 4 TIMER MODE button 5 TIME ADJUST button in 10 minute intervals 6 TIME ADJUST button in 1 minute intervals 7 SG OFF Indicator LED 8 MOVEMENT indicator LED for PIR 9 TIMER MODE indicator LED 10 AUTO MODE indicator LED 11 Motion Sensor window for PIR 12 STOVE OFF indicator LED 13 TIME display 14 Sensor height level adjustment screw to raise or lower the sensor s field of view Normally does not...

Страница 3: ...ED should light Green Sensor LED will light when movement is detected A time of 01 minute should appear on the display A time of 1 minute is the factory default preset Wait about 20 seconds till display shows Dashes means that there is not current detection the stove doesn t draw current Turn on a burner Stove Guard should detect current display will show 01 Test the Stove Guard by standing out of...

Страница 4: ...l show number of minutes left before Stove Guard turn off the stove if no movement is detected If no movement is detected user turn on the stove and left kitchen for the preset time Stove Guard will turn off the stove display will show 00 and red Stove Off indicator 12 on EMU diagram lights The display will show when neither top stove nor oven is turned on no current is detected for more then 4 mi...

Страница 5: ...set the device to the User s particular needs and then password lock it If buttons are locked only the unlock function is enabled To lock unlock Stove Guard s buttons While holding SG OFF button press and hold RIGHT TIME button for 3 seconds Display will show L for lock or U for unlock function depend of previous lock unlock state User has 25 seconds to enter each of four digits 1 to 6 button SG O...

Страница 6: ...tomatically to AUTO Auto On disabled Add 3 Current detection disabled assume always current Add 6 Disabling the current detection is not recommended Turn this setting on only if current detection doesn t work Stove Guard model choose one Standard Add 0 Delay Add 1 Password Add 2 Possible left digit settings 0 8 Right digit meaning Start calculation with 0 Red SG OFF LED meaning choose one Lights w...

Страница 7: ...ent The sensing range of the EMU Electronic Monitoring Unit is over 4 meters around 12 feet at a radius of 110 degrees Each time the motion sensor is activated the green INDICATOR LED flashes 8 on EMU Diagram STOVE GUARD features an adjustable sensing height level to prevent the activation of the stove by small children or pets that might be detected by the motion sensor PIR There is a screw locat...

Страница 8: ...the defective product if returned to SGI within the warranty period and with proof of purchase All STOVE GUARD devices are tested and inspected three times by a qualified electrical inspector and by our own factory before they are packed and shipped STOVE GUARD has been inspected by QPS Field Evaluation Services authorized Agency of Intela Inc Evaluation based on CSA model code SP 1000 for sale in...

Страница 9: ...F E D C B A BLUE BLACK GREEN WHITE RED ORANGE Number 4 Rev Save on Security POWBOXFS PDF File Project Title POWER BOX Fail Safe Stove Guard 1 1 Page September 2006 Date TRANSFORMER T1 7 6 5 2 1 SWITCH_DPDT S1 6 5 4 3 2 1 STEERING_RELAY K3 5 4 3 2 1 POWER_RELAY K2 5 4 3 2 1 POWER_RELAY K1 5 4 3 2 1 JP2 RED BLACK WHITE GREEN JP1 GREEN WHITE BLACK RED CABLE_TO_MONITOR J2 6 5 4 3 2 1 CASE J1 GND GND G...

Страница 10: ...e 10 of 10 User has to add wires drawn in this picture Phase 1 drawn in red Phase 2 black Ground green Neutral yellow white wires in real Transformer Current transformer through House s Power To the Stove ...

Отзывы: