background image

Metropolitan Industries, Inc.

www.metropolitanind.com

StormPro

 

 

OPERATION MANUAL

Battery Back-Up Power Supply 

Dated: 03/15/10

 

Supersedes: 08/31/09

 

Document No.: SP-OM 

Page 4 of 11

Register your product at

www.sumpro.com

5.  If the above items have been thoroughly checked 

and your pump will still not run when plugged into 

the Unit, remove the battery from the battery box 

as described in the assembly instructions and re-

turn the Unit to the place of purchase for repair or 

replacement.

1.  Servicing  of  batteries  should  be  performed  or 

supervised  by  personnel  knowledgeable  of 

batteries and the required precautions.

2.  When  replacing  the  battery,  use  the  same  type 

of battery: (see battery requirements for ordering 

information)

3.  CAUTION-Do not dispose of battery in a fire. The 

battery may explode.

4.  CAUTION-Do  not  open  or  mutilate  the  battery. 

Released  electrolyte  is  harmful  to  the  skin  and 

eyes. It may be toxic.

5.  CAUTION-A battery can present a risk of severe 

burn  and  injury  from  high  short  circuit  current. 

The  following  precautions  should  be  observed 

when working on batteries.

6.  Use tools with insulated handles.

7.  Do  not  lay  tools  or  metal  objects  on  top  of 

batteries.

8.  CAUTION-The  electrolyte  is  a  dilute  sulfuric 

acid  that  is  harmful  to  the  skin  and  eyes.  It 

is  electrically  conductive  and  corrosive.  The 

following procedures should be observed:

a. Wear full eye protection and clothing.

b.  If  electrolyte  contacts  the  skin,  wash  it  off 

immediately.

c.  If  electrolyte  contacts  the  eyes,  flush  thoroughly 

and immediately with water. Seek medical attention.

d. Spilled electrolyte should be washed down with a 

suitable acid neutralizing agent. A common practice 

is to use a solution of approximately one pound (500 

grams)  bicarbonate  of  soda  to  approximately  one 

gallon  (4  liters)  of  water.  The  bicarbonate  of  soda 

solution be added until the evidence of

reaction  (foaming)  has  ceased.  The  resulting  liquid 

should be flushed with water and the area dried.

e. CAUTION- Lead acid batteries can present a risk 

of  fire  because  they  generate  hydrogen  gas.  The 

following procedures should be

followed:

f. DO NOT SMOKE when near batteries.

g. DO NOT cause flame or spark in battery area.

h.  Discharge  static  electricity  from  body  before 

touching batteries by first touching a grounded metal 

surface.

9.  See battery manufacturers installation manual for 

additional  battery  installation  and  maintenance 

instructions. You’re Unit has been designed to be 

virtually  maintenance  free.  Just  make  sure  it  is 

kept clean and dry and that the Unit is periodically 

tested.

1.  Power cord has been cut or the grounding prong 

has been removed.

2.  Unit has been used in an outdoor application.

3.  Batteries  not  meeting  the  above  specifications 

have been used.

4.  Unit has been submerged in water.

5.  Unit  has  been  tampered  with  in  any  manor  not 

described in the above instructions.

6.  Unit has been disassembled by customer.

7.  Unit has been applied to products exceeding the 

maximum capacity of the Unit.

8.  Unit has been applied to the wrong voltage.

9.  The StormPro Back-Up System is used with any 

other  pump  than  the  StormPro  BA-33V  1/3hp 

pump.

Battery Maintenance

Warranty is VOID if...

Содержание 27-AGM

Страница 1: ...attery before handling or making any adjustments to the system Battery Backup Warning 1 Risk of electrical shock this Unit has not been investigated for use in outdoor areas 2 Risk of electrical shock connect only to a properly grounded three pronged grounding type receptacle Under any circumstances do not remove the grounding prong from the power cord 3 Do not smoke use sparkable electrical devic...

Страница 2: ...ay plug the high efficiency pump supplied with the System into the back of the piggyback plug on the Unit DO NOT PLUG ANYTHING OTHER PUMP THAN THE STORMPRO MODEL BA 33V PUMP SUPPLIED WITH THE SYSTEM INTO THE POWER SUPPLY DOING SO WILL VOID THE WARRANTY FUNCTIONS AND LIGHTS The GREEN Power On indicator light should remain on as long as standard line power is available 1 Flashing GREEN light is norm...

Страница 3: ...ower supply Then plug the power supply into the wall outlet 3 Test run your system on AC power by activating the switch then unplug the power supply from the electrical outlet and test the pump on DC power by activating the switch Be sure to plug the power unit plug back into the wall outlet Switch Clamped Securely To Pipe 4 If battery voltage falls below a usable charge PUMP WILLSTOP Power loss i...

Страница 4: ... contacts the eyes flush thoroughly and immediately with water Seek medical attention d Spilled electrolyte should be washed down with a suitable acid neutralizing agent A common practice is to use a solution of approximately one pound 500 grams bicarbonate of soda to approximately one gallon 4 liters of water The bicarbonate of soda solution be added until the evidence of reaction foaming has cea...

Страница 5: ...o actions taken by Metropolitan to correct a defect in a product shall extend the Warranty beyond the period set forth above Metropolitan shall not be obligated to remedy any defect where otherwise required pursuant to the Warranty unless and until Buyer notifies Metropolitan in writing of the defect and then only if such notification is made prior to the expiration of the period set forth above 3...

Страница 6: ...Industries Inc www metropolitanind com StormPro OPERATION MANUAL Battery Back Up Power Supply Dated 03 15 10 Supersedes 08 31 09 Document No SP OM Page 6 of 11 Register your product at www sumpro com French Version ...

Страница 7: ... secteurs extérieurs 2 Le risque de choc électrique mettent seulement correctement à une terre trois le type au sol en plusieurs directions réceptacle Dans aucune circonstance n enlevez pas la fourche fondante du cordon de secteur 3 Ne fumez pas n employez pas les dispositifs électriques sparkable ou la flamme nue en travaillant à cette unité 4 N installez pas l unité dans les endroits classifiés ...

Страница 8: ... système au dos de la prise de ferroutage sur l unité NE BRANCHEZ RIEN L AUTRE POMPE QUE LA POMPE DE STORMPRO MODEL BA 33V FOURNIE AVEC LE SYSTÈME À L ALIMENTATION D ÉNERGIE FAIRE AINSI VIDERA LA GARANTIE FONCTIONS ET LUMIÈRES La lumière VERTE d indicateur de mise en marche devrait rester allumée tant que la ligne standard puissance est disponible Le feu VERT de clignotant est normal et indique qu...

Страница 9: ...otre système sur le courant alternatif En actionnant le commutateur débranchent alors l alimentation d énergie de la sortie électrique et examinent la pompe sur l alimentation CC En actionnant le commutateur Soyez sûr de brancher la prise d unité de puissance de nouveau dans la prise murale Commutateur Maintenu Solidement à Pipe 3 Si la tension de batterie tombe au dessous d une charge utilisable ...

Страница 10: ...ntact avec les yeux éclat complètement et immédiatement avec de l eau Attention médicale de recherche d L électrolyte renversé devrait être lavé vers le bas avec un agent neutralisant acide approprié Une pratique commune est d employer une solution d approximativement un bicarbonate de livre 500 grammes de soude à approximativement un gallon 4 litres de l eau Le bicarbonate de solution de soude so...

Страница 11: ...tropolitaine pour corriger un défaut dans un produit ne prolongera pas la garantie au delà de la période déterminée ci dessus La métropolitaine ne sera pas obligée de ne remédier à d aucun défaut où autrement requis conformément à la garantie à moins qu et jusqu à l acheteur informe la métropolitaine par écrit du défaut et puis seulement si un tel avis est fait avant l expiration de la période dét...

Отзывы: