2020 © Store It Cold, LLC.
9
Rev 2020-8A. All Rights Reserved.
WALK-IN INSTALLATION WITH A FLOOR OPTION
Your walk-in cooler panels, door, screeding, hardware, or outdoor package might differ in design or
looks from the ones shown in this manual and the installation video.
YOUR WALK-IN COOLER HAS BEEN PRE-ASSEMBLED AT THE FACTORY BEFORE CRATING TO ENSURE
PROPER FIT OF ALL PANELS AND TO ENSURE CORRECT DOOR OPERATION.
1.
Set the floor panels according to the
Set-up drawing
included in your documentation. All
panels have labels, and are identified in the
Set-up drawing
.
2.
Make sure that
all floor panels are level
. If not, using
shims
under the floor panels around
the seams and perimeter and
located under the position of the cam-locks is suggested
to
level the floor.