101
Troubleshooting
8.1 Indications on Display
Indication lights
Cause
Remedy
> Constant light
- The appliance is ready
for operation
> Flashing light
- Flow sensor fault
- Water tap closed or
water shortage
Check
- Detergent tank empty
Top up
- Machine scaled
- Spray gun is leaking
Check / replace
- High pressure hose,
coupling or line system
is leaking
> Constant light
> Top up fuel
- Low fuel level
> Cold water operation is
possible
> Constant light
Contact STORCH Ser-
vice
- Service interval has
expired
Contact STORCH Ser-
vice
> Flashing light
Contact STORCH Ser-
vice
- Service interval due in
20 hours
Machine shutdown
Microprocessor error
> Constant light
> Machine shuts down.
Cold water operation is
possible
- Boiler overheated
> Check water supply
Exhaust sensor (EXT-H)
has cut off fuel supply
> Contact STORCH Ser-
vice
- Insuffi cient water fl
ow
- Machine scaled
- Boiler not serviced
> Constant light
Clean fl ame sensor
- Flame sensor (B7) is
sooted
Contact STORCH Ser-
viceständigen
- Ignition or fuel system
failure
Cold water operation is
possible
Original instruction