background image

StorCase Technology, Inc.

DE100i-SW/SWC User's Guide - Rev. G01

12

Installation

8.

Connect the power cable from the DC power supply in the computer or expansion

chassis to the power connector on the DE100 receiving frame.  Refer to Figure

5 for the DE100 receiving frame power connector location.

9.

Replace any expansion boards that may have been removed earlier. Replace

the  system  cover  according  to  the  manufacturer’s  instructions.

10.

Reconnect any system or peripheral cables removed earlier.

11.

Turn ON power to the computer.  If the installation has been successful, and all

cables have been properly attached, the system should boot normally.  Although

the computer may not recognize the DE100 yet, the appropriate front panel LED

indicators should illuminate.

NOTE:

The lock on the DE100 receiving frame functions as a lock and a DC

power switch for the carrier unit.  The lock must be engaged (turned

counterclockwise)  in  order  to  supply  power  to  the  carrier  and

installed drive unit.

12.

The  new  drive  may  need  to  be  formatted  or  initialized  prior  to  use  with  the

operating system and applications software.  Refer to the drive and/or computer

manufacturer's  documentation  for  formatting  information.

Selecting the Unit ID Number

1.

Verify that power is turned on to the DE100 receiving frame by turning on the

computer or external expansion chassis.  A number should appear in the unit

ID display window if the carrier is locked in place.

2.

Unlock the DE100 drive carrier and remove it from the receiving frame. A "u"

will be displayed initially when the unit is unlocked but will return to a number

when the carrier is removed from the receiving frame.

WARNING:

Unlocking the carrier unit switches DC power off to the drive.

Since disk drives require a short amount of time to spin down,

allow about 15 seconds before pulling the carrier unit out of the

receiving frame to avoid possible damage to the drive.

3.

Use the alignment tool supplied with the DE100 to select the ID number of the

disk drive.  Refer to Figure 10 for the location of the Unit ID Select Switch inside

the receiving frame.

4.

After selecting an appropriate unit ID number, replace the DE100 carrier in the

receiving frame, and 

LOCK IT IN PLACE

.

All manuals and user guides at all-guides.com

Содержание Data Express DE100i-SW

Страница 1: ...StorCase Technology Data Express DE100i SW DE100i SWC Removable SCSI Wide Single Ended Drive Enclosures User sGuide All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 2: ...17600 Newhope Street Fountain Valley CA 92708 9885 Phone 714 438 1850 Fax 714 438 1847 StorCase Technology DataExpress DE100i SW DE100i SWC Removable SCSI Wide Single Ended Drive Enclosures User s Gui...

Страница 3: ...of seven 7 years excepting the RAID controller power supply fan and blower components which are covered by the three year warranty described below Three Year Warranty The following StorCase products...

Страница 4: ...foregoing is the complete warranty for the products identified above and supersedes all other warranties and representations whether oral or written StorCase expressly disclaims all warranties for the...

Страница 5: ...Fast Transient EN 60950 CAN CSA C22 2 No 950 93 UL 1950 EN 60950 1988 EN 60950 A2 1991 EN 60950 A1 1990 FCC Part 15 Class B AS NZS 3548 Information Technology Equipment 1997 Company Name Corporate Off...

Страница 6: ...tallation DE100i SW only 7 Installation DE100i SWC only 8 Installing the Receiving Frame 10 Selecting the Unit ID Number 12 Adjusting the Spin Down Up Timer 14 APPENDICES 15 Appendix A Specifications...

Страница 7: ...17 Figure B 1 Attaching the Hot Swap Board 19 Figure B 2 Hot Swap Board Jumper Options 21 Figure B 3 Solenoid Mechanism 22 Figure C 1 Attaching the ON OFF Key 23 Figure D 1 Carrying Case 24 Figure D...

Страница 8: ...seller or StorCase at 800 435 0642 to arrange for a Return Material Authorization RMA StorCase cannot ac cept returns which do not display an RMA number on the outside of the package Return the unit w...

Страница 9: ...6 32 Phillips Flat Hd Mounting Screws 9 1 25mm 2mmIDSelectCable DE100i SW only 1 CableCover 2 AlignmentTool 3 DriveLockKeys 4 ReceivingFrame 5 Drive Carrier 6 InsertSheet 1 2 3 4 7 8 5 6 9 Data Expre...

Страница 10: ...pansion chassis and also provides the ability to secure sensitive data by removing and storing the drive safely for future use Up to fifteen 15 DE100 units can be attached to one host adapter Figure 2...

Страница 11: ...playedtoindicateanunlockedcondition TheunitIDnumberisselected by means of the unit ID select switch inside the receiving frame using a special alignment tool supplied with the DE100 This procedure is...

Страница 12: ...d Pins 15 20 of this connector provide unit SCSI ID selection for the computer system or expansion chassis For remote ID selection through an expansion chassis the unit ID must be set to 0 or open no...

Страница 13: ...itions on the disk drive and remove any jumper plugs in this area The SCSI ID cable will be installed into this section of the drive 5 SCSI ID Cable DE100i SW only Figure 7 The DE100i SW carrier is su...

Страница 14: ...sk drive Figure 6A 3 Install the 5 pin ID select cable into the rear signal distribution board connector Refer to Figure 7 for a typical 2mm drive pin connection 4 Carefully insert the drive into the...

Страница 15: ...ble from the rear distribution board of the DE100i SWC carrier to the disk drive Figure 6B 2 Carefully insert the drive into the carrier at an angle cable end first Make sure not to pinch the cable Lo...

Страница 16: ...he ID select cable to the drive using the 2mm connectors Align the ID0 pin with the black wire Attach the 1 25mm connector on the other end of the ID select cable to the 1 25mm connector J3B provided...

Страница 17: ...any expansion boards that may make installation difficult 3 To select the DE100 unit ID remotely through the computer system or external expansion chassis the appropriate cable from the system must b...

Страница 18: ...a daisy chain the terminators on the receiving frame must be enabled If the DE100 is in the middle of a daisy chain termination should be disabled Refer to jumper W2 in Figure 5 IMPORTANT NOTE In orde...

Страница 19: ...initialized prior to use with the operating system and applications software Refer to the drive and or computer manufacturer s documentation for formatting information Selecting the Unit ID Number 1 V...

Страница 20: ...Unit ID Display Figure 10 Unit ID Select Switch Location NOTE The lock on the DE100 receiving frame serves two functions 1 as a lock to secure the drive and 2 as a DC power switch for the carrier uni...

Страница 21: ...y is turned to the OFF position and when the timer receives a No SCSI Activity signal from the Hot Swap Board it waits the specified delay time before displaying a u on the front panel of the receivin...

Страница 22: ...DE100i SW SWC User s Guide Rev G01 StorCase Technology Inc Appendix A Specifications Dimensions 15 APPENDICES All manuals and user guides at all guides com...

Страница 23: ...90 Altitude 1000 to 50 000 ft 1000 to 50 000 ft 304m to 15240m 304m to 15240m Shock 2 10g 60g 1 Non condensing with maximum gradient of 10 per hour 2 11 msec pulse width 1 2 sine wave Physical Specif...

Страница 24: ...2 x 8 Receiving Frame with Carrier Carrier Only 8 18 207 8mm 0 25 6 4mm 0 15 3 8mm 3 13 79 5mm 5 50 139 7mm 6 32 x 4 Bottom 1 68 42 7mm 4 67 118 6mm 7 38 187 5mm 0 25 6 4mm 0285A 1 75 44 5mm 3 75 95 3...

Страница 25: ...reboot activity will force the SCSI host adapter to rescan its SCSI bus for physically attached drives and will then be able to access the new or changed drive Attaching the Hot Swap Board The DE100i...

Страница 26: ...Options 19 Figure B 1 Attaching the Hot Swap Board 4 Attach the Hot Swap Board to the receiving frame motherboard by using the two screws removed earlier and insert them through the Hot Swap Board in...

Страница 27: ...rtain other users are not accessing the target drive then disable it from the network Dismount the drive 2 Turn the DE100 key lock mechanism located on the front of the receiving frame clockwise to th...

Страница 28: ...ns The jumpers on the Hot Swap Board are similar to those on the standard SCSI Data Express Motherboard See Figure B 2 for the Hot Swap Board jumper options Make sure the factory installed jumper is a...

Страница 29: ...Seagate Barracuda drives require up to 50 seconds Refer to the drive manufacturer s documentation for specific drive information The solenoid lock is controlled by a timing switch located on the side...

Страница 30: ...s OFF to the receiving frame Locate the rectangular shaped key lock mecha nism access hole on the inside of the receiving frame Note that the pawl is in an upright position Insert the key into the key...

Страница 31: ...tic carrying case is designed to transport the DE100 carrier from one site to another in a safe impact and moisture resistant environment Its compact dimensions 7 long x 9 wide x 3 5 high make it easy...

Страница 32: ...The full drive cover P N DX100 COV is an attractive metal cover which can provide additional protection to the drive preventing foreign material from coming in contact with the drive and cables The fu...

Страница 33: ...100 PLUG is designed to fill system or external enclosure bays that are occupied by receiving frames that have no carrier units installed The purpose of the plug is to provide an attractive and functi...

Страница 34: ...ons Everyone at StorCase Technology is working toward the goal of providing you with the highest quality most cost effective products available on the market and we need your comments to guide our eff...

Страница 35: ...UT ALONG THIS LINE FROM BOTTOM TO TOP OF PAGE BUSINESS REPLY MAIL POSTAGE WILL BE PAID BY ADDRESSEE NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES FIRST CLASS MAIL PERMIT NO 10686 SANTA ANA CA TE...

Отзывы: