96006
Ninth Edition (I)
1-7
CAUTION:
Possible component damage:
Do not use a screwdriver to tighten the drive tray latch
knob.
9. Turn the knob all the way to the right to engage the latch and clamp it firmly into the
frame.
10. Pull back on the tray to make sure the tray is securely latched. It should not move.
11. Connect the drive SCSI connector, P903, to the drive.
12. Connect the drive power cable, P904A/B, to the library.
13. Connect the serial interface connector, P6A/B, to the library.
1. P903
2. P904A/B
3. P6A/B
CAUTION:
Possible equipment damage:
Make sure the SCSI cable does not block the fan before
you close the drive door.
Possible cable damage:
Make sure you move the SCSI cable out of the way before
you close the drive door.
Possible component damage:
Do not use a screwdriver to tighten the drive door
latch knob.
14. Close the drive door and secure it by turning the drive door latch knob to your right.
Note:
If you are using the same SCSI ID for the new drive as for the old one, the library will
automatically assign that same address to the new drive and begin functioning as
before. If the operator wants to assign a new address, have the operator follow the
drive configuration procedures in the
L40 Tape Library User’s Guide,
PN 96005; or the
L80 Tape Library User’s Guide,
PN 96021.
Содержание L40 Series
Страница 2: ......
Страница 3: ...L40 80 Tape Library Drives Customer Replaceable Unit CRU Instructions...
Страница 6: ...Summary of Changes iv Ninth Edition I 96006 This page intentionally left blank...
Страница 8: ...Contents vi Ninth Edition I 96006...
Страница 12: ...x Ninth Edition I 96006 This page intentionally left blank...
Страница 23: ...96006 Ninth Edition I 1 3 Figure 1 1 L40 Drive CRU Location L201_118...
Страница 24: ...1 4 Ninth Edition I 96006 Figure 1 2 L80 Drive CRU Location L L201_298...
Страница 28: ...1 8 Ninth Edition I 96006...