Alarm Input and Output
Connect PTZ
Tips:
Video Output: VGA/Monitor
(
CVBS Output
)
The alarm input device should be the type of GND connected alarm or voltage input alarm, Can be
N/O(normally open) or N/C(normally closed).
The level request of voltage-mode alarm signal: low level range: 0~2V, high level range: 5~15V.
The green angle pins of signal cable are supplied for access of PTZ and alarming devices. Please follow
these steps to connect:
Pull out the green angle pins.
Loosen the screws on the plug by small crosshead screwdriver. Put the signal line under the spring piece
inside the plug, tighten the screws.
Plug in the connected pins into green angle pin socket.
Connect the PTZ control interfaces to RS422 TX+ and TX- in the rear panel. The method is as
Some PTZ have different communication protocol, baud rate and address code. Please refer to the
instruction and setup the matched parameter.
1
2
3
.
.
.
above.
File Download :
Note 1:
Note 2:
The product support update way:
By USB:
By IE:
By user port software:
HD Capacity:
Haredware Edition:
Software Edition:
Issue Date:
The File download operation part is on the right bottom of the screen.
Click
to set the storage directory of the file selected. Click
〖
Download
〗
to start downloading.
4.8.2.4
4.8.2.5
4.9.1
4.9.2
Remote Log Review
Remote Equipment Update
Equipment Maintenance
Log Review
System Update
Equipment Information
Click
to enter interface of Log search and Backup. Log search support 4 way of searching: All,
Type, Time ,Type & Time. Choose search way and channel no., and click SEARCH to have log
information that tally with require.
Enter selection of Equipment Parameter, Equipment manage. User Browse to choose file that needs
upgrading, click Start for upgrading. In case exception accure during upgrading, choose stop upgrade to
stop your operation.
Enter Tool ,System Menu, Equiepemnt maintainance interface to have operation of maintain for
correlative equipment
1. Choose log type that you want to check: All/ Operation/ Exception/ Alarm
2. Choose the time that you you want to check
3. Press Search, detail information is showed on interface
When there s record informtaion in your search result, enter
on right side of the log to play.
Log can record max 30000pcs record currently. The way of record wash out: To replace the
earliest log information autoly.
Local USB, IE, User port software
Make sure USB is correctly connected and upgrade program is copied in USB before operation.
Upgrading by tips on the interface.
After upgrading, there will Reboot tips on the screen. The system would run with new software when
rebootted.
Please refer to 4.8.2.2
Please refer to illustrate of User port software
Show the capacity and left capacity of current HD that connects to equipment.
Show information of current Hardware Edition
Show information of current software Edition
Show issue date of current software.
4.9
4.9.3
'
【 】
LCD WITH BUILT-IN DVR USER MANUAL
LCD WITH BUILT-IN DVR USER MANUAL