StoneAge NA60IND Скачать руководство пользователя страница 2

 

2

 

 

Table 1. Fireplace Components  

Item  

Description 

Base Plate 

1C 

Base Plate Extension 

Lower & Middle Sidewall 

3AL 

Bottom Back Plate - Left 

3BL 

Bottom Back Plate - Right 

3CL 

Bottom Back Plate – Center Extension 

3A 

Lower Back Plate - Left 

3B 

Lower Back Plate - Right 

3C 

Lower Back Plate – Center Extension 

4A 

Middle Back Plate - Left  

4B 

Middle Back Plate - Right 

4C 

Middle Back Plate – Center Extension 

5A 

Upper Back Plate - Left 

5B 

Upper Back Plate - Right 

5C 

Upper Back Plate – Center Extension 

Upper Slanted Sidewall - Right 

Upper Slanted Sidewall - Left 

Front Header 

Lower Throat – Right Front 

9C 

Lower Throat – Center Front Extension 

10 

Lower Throat – Left Front 

11 

Lower Throat – Left Rear 

11C 

Lower Throat – Center Rear Extension 

12 

Lower Throat – Right Rear 

13 

Middle Throat – Right Rear 

14 

Middle Throat – Right Front 

14C 

Middle Throat – Center Front Extension 

15 

Middle Throat – Left Front 

16 

Middle Throat – Left Rear 

16C 

Middle Throat – Center Rear Extension 

17 

Upper Throat – Right Rear 

18 

Upper Throat – Right Front 

18C 

Upper Throat – Center Front Extension 

19 

Upper Throat – Left Front 

20 

Upper Throat – Left Rear 

20C 

Upper Throat – Center Rear Extension 

21 

Throat Cap – Left 

21C 

Throat Cap – Center Front Extension 

22 

Throat Cap – Right 

22C 

Throat Cap – Center Rear Extension 

23B 

Double Flue Adapter 

23 (not shown) 

Masonry Chimney Blocks or Metal Flue Adapters  

2.1 Specifications 

Table 2: Clearances (See Figure 3) 

NA 60 Fireplace  

Item 

Clearance 

Figure 2 
Refer-
ence 

Backwall 

 

Sidewalls 

0 to Appliances 
18” from Fireplace open-
ing at points in front of 
fireplace 

 

Floor: Non 
combustible 
extending 
as follows 

20” when hearth is less 
than 6” from floor 
18” when hearth is greater 
than 6” from floor 

12” Mantle 

60” from hearth 

Top Trim 

48” from hearth 

Side Trim 

6” from fireplace opening 

Front en-
closure 

Non combustible from 
hearth up 36.” (E-1) 
Combustible 36” from 
hearth (E-2) 
 

Hearth 

If  the fireplace opening is 
6 sq feet or larger, the 
hearth shall extend at least 
20 inches in front of the 
opening and 12 inches 
beyond each side.  If the 
opening is less than 6 sq 
feet, the hearth shall ex-
tend at least 16 inches in 
front of the opening and 8 
inches beyond each side. 

 

Clearance 
around 
chimney 

0” New Age Chimney 
Block 
2” Metal Pipe chimney 
(UL 103 and ULC S604) 

Chimney 
Height 

16’ from floor  

 

 

Note 1:

 This Fireplace intended for use with solid wood 

fuel or vented gas logs.  

CAUTION: When using this appliance, the fire-

place damper must be set in the fully open 
position. 

Note  2:

  This  fireplace  has  not  been  tested  for  use  with 

glass doors.  

 

Note 3:

 Do not use fireplace insert or other products not 

specified  for  use  with  this  model.    Use  a  fireplace  grate 
when burning wood. 

Note 4: 

Clay flue liners installed in flue section meet the 

specifications of ASTM Section C315-02. 

1

2

2

3A 

3B

4A

4B

5A 

5B

6

10 

11 

12

13

14 

15 

16 

17

18 

19 

20

21 

22 

3AL 

3CL 

3BL

Figure 2. Fireplace Components 

3C 

4C 

5C 

9C 

11C 

14C 

18C 

16C 

20C 

21C 

22C

 

1C 

1

23B

2

Содержание NA60IND

Страница 1: ...se instructions for future use 2 0 Description The fireplace is delivered as a kit with all compo nents necessary to complete the installation The kit is configured for a flue chimney but a special ad...

Страница 2: ...2 Clearances See Figure 3 NA 60 Fireplace Item Clearance Figure 2 Refer ence Backwall 0 Sidewalls 0 to Appliances 18 from Fireplace open ing at points in front of fireplace Floor Non combustible exte...

Страница 3: ...t important that the Stone Age fireplace be installed according to the following instructions It is also important that local building codes be consulted and followed Improper installation could resul...

Страница 4: ...to back See Figure 4 C Install the bottom sidewalls 2 first followed by the bottom back plate pieces 3AL 3BL 3CL On the second level install the sidewalls 2 first then the back plates 3A 3B 3C so tha...

Страница 5: ...t lip resting on the front header 8 Mortar damper in place Ensure the damper opens and closes properly I Install the first complete ring of four interlock ing throat components items 9 9C 10 11 11C an...

Страница 6: ...Figures 17 and 18 M Install Stone Age masonry chimney system consisting of clay liners and outer blocks or Stone Age Pipe Adapters if installing a metal pipe chim ney See Figures 19 and 20 13 14 16 15...

Страница 7: ...y system consisting of proprietary outer blocks and clay flues or metal pipe chimney pipe tested and certified to UL 103 standards for the US and ULC S604 standards for Canada 4 1 Stone Age Masonry Sy...

Страница 8: ...of pitch J Use mortar to create a slope away from the clay flue running out to the edge of the finish material to assist with water drainage Install the chimney cap following instructions provided Thi...

Страница 9: ...then be larger depending on the pitch of the roof See Figure 23 F Frame the opening ensuring that the recom mended minimum clearance to combustibles by the chimney pipe manufacturer exists between the...

Страница 10: ...Never throw kick or by any other means force wood into the firebox as this could damage the firebrick and fireplace walls that could result in permanent damage and void the war ranty Stress cracks fro...

Страница 11: ...ire at one time can result in over firing and too much heat in the firebox causing damage to the fireplace D When lighting a fire in a cold chimney a downdraft may be created letting a little smoke in...

Страница 12: ...sure it is returned prior to laying the next fire D Keep the fireplace screen clean so air flows freely through it E Spot check the refractory bricks and mortar for small cracks It will expand slightl...

Страница 13: ...13...

Страница 14: ...turing defects in the Stone Age product and does not cover de fects or faulty workmanship in the installation of the product or the ma sonry or other structure in which it is installed Also this warra...

Отзывы: