X
NOTE: If all 4 of the arms are being angled, each arm should be
angled 1/2 of the chart value.
!!!WARNING!!!
The angle of the arms controls the rotation speed and direction.
Always angle the arms so that the jet torque tightens the manifold
onto the swivel shaft. (Clockwise when viewed from the bottom.)
Increasing the angle will increase the rotation speed.
X
3.1 Angle Settings/Adjustment
02/03
10
15
2 0
25
30
3 5
20000
.024Ø
16°
.032Ø
10°
.035Ø
8°
.038Ø
7°
.042Ø
5°
.047Ø
4°
15000
.029Ø
12°
.035Ø
8°
.038Ø
7°
.042Ø
5°
.047Ø
4°
.052Ø
4°
10000
.032Ø
11°
.038Ø
8°
.042Ø
6°
.047Ø
5°
.052Ø
4°
.057Ø
3°
5000
.038Ø
10°
.042Ø
8°
.052Ø
6°
.057Ø
5°
.063Ø
4°
.069Ø
3°
Pressure,PSI
Flow Rate, GPM
.0XXØ
α
°
Orifice Diameter for pressure and flow with 4 jets.
Angle of 2 arms for approximately 1000 RPM