StoneAge FC-SG Скачать руководство пользователя страница 1

www.stoneagetools.com          [email protected]

OPERATION AND MAINTENANCE 

FLOOR CLEANER

WATERBLAST 

FC-SV

FC-SG

MANUAL

54 Girard St.   Durango, Colorado  81303      (970) 259-2869 Phone   (970) 259-2868 Fax

© 09/05

Содержание FC-SG

Страница 1: ...www stoneagetools com sales stoneagetools com OPERATION AND MAINTENANCE FLOOR CLEANER WATERBLAST FC SV FC SG MANUAL 54 Girard St Durango Colorado 81303 970 259 2869 Phone 970 259 2868 Fax 09 05 ...

Страница 2: ...ng tool use Please read and follow all of these instructions in addition to the guidelines in the WJTA Recommended Practices handbook 1 1 Only competent and trained persons should operate this equipment 1 2 Do not exceed the maximum operating pressure specified for any component in a system 1 3 This equipment should always be used with an operator controlled dump mechanism to release the high pres...

Страница 3: ...ome skirt is too close to the ground water may accumulate and result in an irregular rotation speed The maximum safe rotation speed for the assembly is 1500 rpm WATER SUPPLY A clean and dependable source of water is required Flow rates in excess of 30 gpm may require additional weight to hold the unit down A 10 micron water filter upstream from the pump is recommended Flush all hoses before use Ke...

Страница 4: ...se when viewed from the bottom Increasing the angle will increase the rotation speed X 3 1 Angle Settings Adjustment 02 03 10 15 20 25 30 35 20000 024Ø 16 032Ø 10 035Ø 8 038Ø 7 042Ø 5 047Ø 4 15000 029Ø 12 035Ø 8 038Ø 7 042Ø 5 047Ø 4 052Ø 4 10000 032Ø 11 038Ø 8 042Ø 6 047Ø 5 052Ø 4 057Ø 3 5000 038Ø 10 042Ø 8 052Ø 6 057Ø 5 063Ø 4 069Ø 3 Pressure PSI Flow Rate GPM 0XXØ α Orifice Diameter for pressure...

Страница 5: ...t 2 FC 135 27 Rail Chassis pair 1 FC 137 27 Clamp rubber skirt 1 FC 139 Spacer Block 2 FC 190 Inlet Hose 1 FC 192 M Coupler type M 1 FC 192 P8 Coupler P8 1 FC 200 27 Push Handle 1 FC 203 Dump Handle Pin 1 FC 302 Dump Cable 1 FC 306 Dump Handle 1 FC 307 Cotter Pin 2 FC 311 Dump Hose 1 FC 312 Fitting 1 JIC 3 4 NPT 1 FC 313 Dump Hose Fitting 1 SG CRS M12K Swivel 1 used in vacuum assembly 15 000 psi M...

Страница 6: ...s FC 135 27 RH Skirt Brush FC 113 Wheel Caster 2 FC 124 FC 130 27V FC 112 Rail Chassis Nipple FC 018 SG FC 133 27 Splash Guard Skirt Rubber FC 131 27 FC 200 27 Push Handle FC 203 Dump Handle Pin FC 311 Dump Hose FC 302 Dump Cable FC 139 Spacer Block 2 FC 123 Vacuum Elbow Wheel fixed 2 12K CRS M Swivel Dome or FC 134 Clamp 2 or FC 137 27 FC 122 Mount Collar ...

Страница 7: ... Dome Upright Mounts See above pictures The stationary Non Caster wheel is mounted to the front of the Chassis Frame Assembly Mount Type A This configuration allows for maneuverability and ease of turning The rear Mount Points on the Chassis Frame Assembly are attached to the Dome Upright Mounts See above pictures The stationary Non Caster wheel is mounted to the rear of the Chassis Frame Assembly...

Страница 8: ...nifold autoclave fittings to connect the arms to the Mouning Collar Half 2 FC 122 Swivel Swivel SG CRS M12K Plate FC 144 3 Assembly 20 Kpsi Head Arm Clamp 4 FC 147 A12 Arm 4 FC 160 24 95A12 Nozzle Guard 4 FC 172 Antivibe Gland 4 AF 072 There are two different head units that can be Distinguishing between Pipe Threads Fittings and Autoclave Fittings is rather simple Pipe Threads consist of a tapere...

Страница 9: ...the option of requiring the return of the defective products to its factory with transportation charges prepaid to establish the claim StoneAge Inc shall in no event be held liable for damages or delay resulting from or arising out of defective products nor for consequential damages or otherwise except for repair or replacement of items of defective material or workmanship aforesaid THIS WARRANTY ...