![Stone Age SA-24PS Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/stone-age/sa-24ps/sa-24ps_installation-and-operation-instructions-manual_1382035002.webp)
2
Table 1. Fireplace Components
Item Description
Dimensions
2
Base Plate
33” x 34”
3
Sidewall
11” x 33”
4
Back Plate
22.5” x 27”
8
Throat
19” x 19”
at top
9A
Flue (Note 2)
19” x 19”
Note 1
: Item numbers refer to component numbers in Figure 2.
Note 2
: Additional flue sections may be added to this fireplace,
up to a maximum of four feet. Additional flue sections must be
purchased separately.
Note: Drawings of the fireplace components,
with dimensions, are shown on page 10.
2.1 Specifications
Table 2: Clearances (See Figure 3)
Item
Clearance
Figure 3
Reference
Sidewall to Opening
18”
Top Trim to Opening
17”
A
Side Trim to Opening
3”
Mantle to Opening
25”
B
Floor to Opening
7”
Front Hearth Extension
24”
C
Side Hearth Extension
12”
D
Opening to Combustibles
48”
Clearance around Chimney
flue
2”
Note 1
. This Fireplace is intended for use with solid wood fuel
or vented gas logs
Note 2:
This fireplace has not been tested for use with glass
doors. To reduce the risk of fire or injury, do not install glass
doors.
Note 3:
Do not use fireplace insert or other products not speci-
fied for use with this model. Use a fireplace grate when burning
wood.
Note 4:
This fireplace has not been tested with an unvented gas
log. Do not install an unvented gas log set into this fireplace.
Note 5:
Clay flue liners installed in flue section (item 9A, Figure
2) meet the specifications of ASTM Section C315-02.
Note 6:
Make sure installation complies with local building
codes.
Note 7:
Floor under unit must be non-combustible to earth
2.2 Installation of Additional Equipment
WARNING: THIS FIREPLACE HAS NOT
BEEN TESTED FOR USE WITH
DOORS. TO REDUCE THE RISK
OF FIRE OR INJURY, DO NOT
INSTALL GLASS DOORS.
A. Do not install a fireplace insert unless it is tested
with this fireplace.
B. Cutting or drilling a hole into the floor or walls
for gas supply for a vented decorative gas appliance
(log), fresh air venting, or an ash dump, is accepta-
ble.
C. If a decorative gas appliance is installed, it must
be installed in accordance with the National Gas Fire
Code, ANSI Z223.1.
D. It must incorporate an automatic shutoff device.
E. Installation must comply with the Standard for
Decorative Gas Appliances in Vented Appliances,
ANSI Z21.60 (1991) or American Gas Association
draft requirements for Gas-Fired Log Lighters for
Burning Fireplaces, Draft No. 4 dated August 1993.
Figure 3. SA-24PS Mantel & Hearth