Stone Age NA48 Скачать руководство пользователя страница 2

 

2

 

 
 

Table 1. Fireplace Components  

Item  

Description 

Base Plate 

2A 

Sidewall Height Extension 

Lower & Middle Sidewall 

Back Plate Height Extension 

3A 

Lower Back Plate - Left 

3B 

Lower Back Plate - Right 

4A 

Middle Back Plate - Left  

4B 

Middle Back Plate - Right 

5A 

Upper Back Plate - Left 

5B 

Upper Back Plate - Right 

Upper Slanted Sidewall - Right 

Upper Slanted Sidewall - Left 

Front Header 

Lower Throat – Right Front 

10 

Lower Throat – Left Front 

11 

Lower Throat – Left Rear 

12 

Lower Throat – Right Rear 

13 

Middle Throat – Right Rear 

14 

Middle Throat – Right Front 

15 

Middle Throat – Left Front 

16 

Middle Throat – Left Rear 

17 

Upper Throat – Right Rear 

18 

Upper Throat – Right Front 

19 

Upper Throat – Left Front 

20 

Upper Throat – Left Rear 

21 

Throat Cap – Right 

22 

Throat Cap - Left 

23 

Masonry Chimney Block or Metal Flue 
Adapter (Sold separately, Not shown) 

2.1 Specifications 

Table 2: Clearances (See Figure 3) 

NA 48 Fireplace  

Item 

Clearance 

Figure 2 
Refer-
ence 

Backwall 

 

Sidewalls 

0 to Appliances 
18” from Fireplace open-
ing at points in front of 
fireplace 

 

Floor: Non 
combustible 
extending 
as follows 

20” when hearth is less 
than 6” from floor 
18” when hearth is greater 
than 6” from floor 

12” Mantle 

48” from hearth 

Top Trim 

36” from hearth 

Side Trim 

6” from fireplace opening 

Front en-
closure 

Non combustible from 
hearth up 36.” (E-1) 
Combustible 36” from 
hearth (E-2) 
 

Hearth 

If  the fireplace opening is 
6 sq feet or larger, the 
hearth shall extend at least 
20 inches in front of the 
opening and 12 inches 
beyond each side.  If the 
opening is less than 6 sq 
feet, the hearth shall ex-
tend at least 16 inches in 
front of the opening and 8 
inches beyond each side. 

 

Clearance 
around 
chimney 

0” New Age Chimney 
Block 
2” Metal Pipe chimney 
(UL 103 and ULC S604) 

Chimney 
Height 

16’ from floor  

 

 

Note 1:

 This Fireplace intended for use with solid wood 

fuel or vented gas logs.  

CAUTION: When using this appliance, the fire-

place damper must be set in the fully open 
position. 

Note  2:

  This  fireplace  has  not  been  tested  for  use  with 

glass doors.  

 

Note 3:

 Do not use fireplace insert or other products not 

specified  for  use  with  this  model.    Use  a  fireplace  grate 
when burning wood. 

Note 4: 

Clay flue liners installed in flue section meet the 

specifications of ASTM Section C315-02. 

2

2

3A 

3B 

4A

4B 

5A 

5B 

6

10 

11 

12

13

14 

15 

16 

17

18 

19 

20 

21 

22

2A 

2A

Figure 2. Fireplace Components 

Содержание NA48

Страница 1: ...kit with all compo nents necessary to complete the installation The kit is configured for a flue chimney but a special adapt er is available for a metal chimney Component ar rangement some of which is...

Страница 2: ...0 when hearth is less than 6 from floor 18 when hearth is greater than 6 from floor A 12 Mantle 48 from hearth B Top Trim 36 from hearth C Side Trim 6 from fireplace opening D Front en closure Non com...

Страница 3: ...t important that the Stone Age fireplace be installed according to the following instructions It is also important that local building codes be consulted and followed Improper installation could resul...

Страница 4: ...or addi tional reinforcement if desired B When the base is level and square set the base plate 1 Level it from side to side and front to back See Figure 4 C Install the sidewall and back plate extensi...

Страница 5: ...g toward front of the fireplace The bottom lip of the damper should rest on the fire brick with the front lip resting on the front header 8 Mortar damper in place Ensure the damper opens and closes pr...

Страница 6: ...Install Stone Age masonry chimney system consisting of clay liners and outer blocks or Stone Age Pipe Adapter if installing a metal pipe chim ney See Figures 18 and 19 N If installing a mantel and si...

Страница 7: ...ay flues or metal pipe chimney pipe tested and certified to UL 103 standards for the US and ULC S604 standards for Canada 4 1 Stone Age Masonry System The Stone Age Masonry chimney system consists of...

Страница 8: ...nstall the metal chimney following the instructions below and the instructions provided by the chimney pipe manufacturer Install a Stone Age masonry pipe adapter sold sepa rately to the top of the fir...

Страница 9: ...LS G Continue to add pipe sections extending the chimney through the roof H A wood chase may be constructed around the exposed chimney for aesthetic effect Ensure the minimum recommended clearances to...

Страница 10: ...the war ranty Stress cracks from thermal cycling are nor mal H Do not alter this fireplace to the extent that it would jeopardize the structural integrity of the fire place Drilling or cutting a hole...

Страница 11: ...g a little smoke into the room To correct this hold a wadded newspaper in the firebox and light it This will cre ate an updraft and clear the flue of cold air The following steps are recommended when...

Страница 12: ...air flows freely through it E Spot check the refractory bricks and mortar for small cracks It will expand slightly with the heat and then contract as it cools Replace refractory bricks when the crack...

Страница 13: ...13...

Страница 14: ...cturing defects in the Stone Age product and does not cover de fects or faulty workmanship in the installation of the product or the ma sonry or other structure in which it is installed Also this warr...