Stone Age NA36IND Скачать руководство пользователя страница 2

 

2

 

 
 

Table 1. Fireplace Components  

Item  

Description 

Base Plate 

Lower & Middle Sidewall 

3A 

Lower Back Plate 

3B 

Lower Back Plate 

4A 

Middle Back Plate 

4B 

Middle Back Plate 

5A 

Upper Back Plate 

5B 

Upper Back Plate 

Upper Slanted Sidewall - Right 

Upper Slanted Sidewall - Left 

Front Header 

Lower Throat – Right Front 

10 

Lower Throat – Left Front 

11 

Lower Throat – Left Rear 

12 

Lower Throat – Right Rear 

13 

Middle Throat – Right Rear 

14 

Middle Throat – Right Front 

15 

Middle Throat – Left Front 

16 

Middle Throat – Left Rear 

17 

Upper Throat – Right Rear 

18 

Upper Throat – Right Front 

19 

Upper Throat – Left Front 

20 

Upper Throat – Left Rear 

21 

Throat Cap – Right 

22 

Throat Cap - Left 

23 

Masonry Chimney Block or Metal Flue 
Adapter (Sold separately, Not shown) 

2.1 Specifications 

Table 2: Clearances (See Figure 3) 

NA 36 Fireplace  

Item 

Clearance 

Figure 2 
Reference 

Backwall 

 

Sidewalls 

0 to Appliances 
18” from Fireplace opening 
at points in front of fire-
place 

 

Floor: Non 
combustible 
extending 
as follows 

20” when hearth is less than 
6” from floor 
18” when hearth is greater 
than 6” from floor 

12” Mantle 

48” from hearth 

Top Trim 

36” from hearth 

Side Trim 

6” from fireplace opening 

Front en-
closure 

Non combustible from 
hearth up 36.” (E-1) 
Combustible 36” from 
hearth (E-2) 

Hearth 

If  the fireplace opening is 6 
sq feet or larger, the hearth 
shall extend at least 20 
inches in front of the open-
ing and 12 inches beyond 
each side.  If the opening is 
less than 6 sq feet, the 
hearth shall extend at least 
16 inches in front of the 
opening and 8 inches be-
yond each side. 

 

Clearance 
around 
chimney 

0” New Age Chimney 
Block 
2” Metal Pipe chimney (UL 
103 and ULC S604) 

Chimney 
Height 

16’ from floor  

 

 

Note  1:

  This  Fireplace  intended  for  use  with  solid  wood 

fuel or vented gas logs.  

CAUTION: When using this appliance, the fireplace 

damper must be set in the fully open posi-
tion. 

Note 2:

 This fireplace has not been tested for use with glass 

doors.  

 

Note  3:

  Do  not  use  fireplace  insert  or  other  products  not 

specified  for  use  with  this  model.    Use  a  fireplace  grate 
when burning wood. 

Note  4: 

Clay  flue  liners  installed  in  flue  section  meet  the 

specifications of ASTM Section C315-02. 

2

2

3A 

3B 

4A

4B 

5A 

5B 

6

10 

11 

12

13

14 

15 

16 

17 

18 

19 

20 

21 

22 

Figure 2. Fireplace Components 

Содержание NA36IND

Страница 1: ... kit with all components necessary to complete the installation The kit is con figured for a flue chimney but a special adapter is available for a metal chimney Component arrange ment some of which is optional is shown in Figure 2 Components are shown in Table 1 Specifications and installation dimensions are shown in Table 2 A completed installation should include the following A Fireplace items s...

Страница 2: ... when hearth is greater than 6 from floor A 12 Mantle 48 from hearth B Top Trim 36 from hearth C Side Trim 6 from fireplace opening D Front en closure Non combustible from hearth up 36 E 1 Combustible 36 from hearth E 2 E Hearth If the fireplace opening is 6 sq feet or larger the hearth shall extend at least 20 inches in front of the open ing and 12 inches beyond each side If the opening is less t...

Страница 3: ...t important that the Stone Age fireplace be installed according to the following instructions It is also important that local building codes be consulted and followed Improper installation could result in Overheating leading to fireplace failure Leakage of rainwater through and around the chimney Cracks and settling because of poor founda tions Emission of smoke sparks and gases into the living ar...

Страница 4: ... mortar for additional reinforcement if desired B When the base is level and square set the base plate 1 Level it from side to side and front to back See Figure 4 C Install the sidewall pieces 2 and the lower and middle back plates 3A 3B and 4A 4B Use 3 8 joint of mortar between each section Smooth out mortar and ensure sections remain level See Figures 5 and 6 D Lay a straightedge across the left...

Страница 5: ...k with the front lip resting on the front header 8 Mortar damper in place Ensure the damper opens and closes properly I Install the first complete ring of four interlocking throat components items 9 10 11 and 12 Check with a level See Figure 13 J Install second ring of four throat components Items 13 14 15 16 Check with a level See Figure 14 8 9 10 11 12 Figure 13 Lower Throat Level Figure 10 Fron...

Страница 6: ...g of clay liners and outer blocks or Stone Age Pipe Adapter if installing a metal pipe chimney See Figures 17 and 18 N If installing a mantel and side trim especially if it is wood or other combustible materials ensure the 13 14 16 15 17 18 19 20 21 22 23 Outer Block 23 Pipe Adapter 22 Clay Flue 22 21 21 Figure 18 Metal Pipe Chimney Figure 17 Stone Age Masonry Chimney Figure 14 Middle Throat Level...

Страница 7: ...pipe tested and certified to UL 103 standards for the US and ULC S604 standards for Canada 4 1 Stone Age Masonry System The Stone Age Masonry chimney system consists of stacking Stone Age chimney blocks and installing a clay flue inside A Place a clay flue inside the chimney block The holes in each corner of the chimney block allow the placement of rebar and mortar for additional rein forcement if...

Страница 8: ...provided by the chimney pipe manufacturer Install a Stone Age masonry pipe adapter sold sepa rately to the top of the firebox using a 14 I D adapt er for the NA 36 Connect the first pipe section to the metal adapter as shown in Figure 23 Chimney plumbing can either be straight through the ceiling and through the roof or if the fireplace is installed on an outside wall the chimney can be external t...

Страница 9: ...ections extending the chimney through the roof H A wood chase may be constructed around the exposed chimney for aesthetic effect Ensure the minimum recommended clearances to combustibles specified by the metal chimney pipe manufacturer are maintained inside the chase I Install roof flashing appropriate to the roof pitch and any other pipe accessories per the pipe manufac turer s instructions J Ins...

Страница 10: ...re nor mal H Do not alter this fireplace to the extent that it would jeopardize the structural integrity of the fire place Drilling or cutting a hole for a gas line fresh air vent or ash dump is acceptable Use only Stone Age authorized equipment with this fireplace 5 2 Selection of Wood Use cured wood logs only Scrap wood produces sparks Treated wood coal or woods dipped in pine tar should not be ...

Страница 11: ... the firebox and light it This will create an updraft and clear the flue of cold air The following steps are recommended when starting a fire A Remove any excess ash from the fireplace Ex cessive ash may reduce airflow Some owners prefer to leave a small layer to insulate the cold refractory brick below the grate helping fire starting B Open and close the damper to ensure it operates properly Leav...

Страница 12: ...air flows freely through it E Spot check the refractory bricks and mortar for small cracks It will expand slightly with the heat and then contract as it cools Replace refractory bricks when the cracks open more than or when pits become extensive and deeper than 3 16 or when any piece of refractory larger than 2 inches in diameter becomes dislodged F If creosote has accumulated it should be re move...

Страница 13: ...13 ...

Страница 14: ...cturing defects in the Stone Age product and does not cover de fects or faulty workmanship in the installation of the product or the ma sonry or other structure in which it is installed Also this warranty does not cover items that have been damaged due to over heating modifica tion improper storage or maintenance Stone Age shall repair or re place at its option any defective Stone Age product comp...

Отзывы: