![Stone Age NA36IND Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/stone-age/na36ind/na36ind_assembly-installation-and-operation-instructions_1382019002.webp)
2
Table 1. Fireplace Components
Item
Description
1
Base Plate
2
Lower & Middle Sidewall
3A
Lower Back Plate
3B
Lower Back Plate
4A
Middle Back Plate
4B
Middle Back Plate
5A
Upper Back Plate
5B
Upper Back Plate
6
Upper Slanted Sidewall - Right
7
Upper Slanted Sidewall - Left
8
Front Header
9
Lower Throat – Right Front
10
Lower Throat – Left Front
11
Lower Throat – Left Rear
12
Lower Throat – Right Rear
13
Middle Throat – Right Rear
14
Middle Throat – Right Front
15
Middle Throat – Left Front
16
Middle Throat – Left Rear
17
Upper Throat – Right Rear
18
Upper Throat – Right Front
19
Upper Throat – Left Front
20
Upper Throat – Left Rear
21
Throat Cap – Right
22
Throat Cap - Left
23
Masonry Chimney Block or Metal Flue
Adapter (Sold separately, Not shown)
2.1 Specifications
Table 2: Clearances (See Figure 3)
NA 36 Fireplace
Item
Clearance
Figure 2
Reference
Backwall
0
Sidewalls
0 to Appliances
18” from Fireplace opening
at points in front of fire-
place
Floor: Non
combustible
extending
as follows
20” when hearth is less than
6” from floor
18” when hearth is greater
than 6” from floor
A
12” Mantle
48” from hearth
B
Top Trim
36” from hearth
C
Side Trim
6” from fireplace opening
D
Front en-
closure
Non combustible from
hearth up 36.” (E-1)
Combustible 36” from
hearth (E-2)
E
Hearth
If the fireplace opening is 6
sq feet or larger, the hearth
shall extend at least 20
inches in front of the open-
ing and 12 inches beyond
each side. If the opening is
less than 6 sq feet, the
hearth shall extend at least
16 inches in front of the
opening and 8 inches be-
yond each side.
Clearance
around
chimney
0” New Age Chimney
Block
2” Metal Pipe chimney (UL
103 and ULC S604)
F
Chimney
Height
16’ from floor
Note 1:
This Fireplace intended for use with solid wood
fuel or vented gas logs.
CAUTION: When using this appliance, the fireplace
damper must be set in the fully open posi-
tion.
Note 2:
This fireplace has not been tested for use with glass
doors.
Note 3:
Do not use fireplace insert or other products not
specified for use with this model. Use a fireplace grate
when burning wood.
Note 4:
Clay flue liners installed in flue section meet the
specifications of ASTM Section C315-02.