Stone Age NA36IND Скачать руководство пользователя страница 1

 

1

 

Report 307-F-02b-2 

 

Installation and Operation  

Instructions 

Stone Age Indoor Fireplace 

 

 

 

1.0 Introduction  

The following provides instructions for the installation 
and  operation  of  the  Stone  Age  Fireplace,  manufac-
tured by Stone Age Manufacturing, Collinsville, Okla-
homa. 

Three generations of fireplace knowledge and experi-
ence have gone into the design and construction of the 
New Age series fireplaces.    New Age Fireplaces are 
certified to UL127 for the US, and ULCS610 for Can-
ada.   They are also certified in accordance with ICC-
ES AC156 meeting structural design requirements for 
Earthquake  Testing  at  a  compliance  level  of  Sds  = 
2.5g.  The ICC-ES AC156 complies with 2010 Ameri-
can  Society  of  Civil  Engineers  (ASCE)  7-10,  2009 
International  Building  Code  (IBC),  2010  California 
Building Code and 2012 ICC-ES AC156.   Assembly 
and  Cutaway  views  of  a  NA36IND  fireplace  are 
shown in Figure 1.   

 

 

Because of structural modifications required in an ex-
isting  home,  it  is  recommended  that  this  fireplace  be 
installed by a professional installer, or by a builder in 
new  construction.  Installation by a non-qualified per-
son may negate the warranty. 

Keep these instructions for future use.  

2.0 Description 

The fireplace is delivered as a kit with all components 
necessary to complete the installation.  The kit is con-
figured  for  a  flue  chimney,  but  a  special  adapter  is 
available  for  a  metal  chimney.    Component  arrange-
ment, some of which is optional, is shown in Figure 2.  
Components are shown in Table 1.  Specifications and 
installation dimensions are shown in Table 2. 

A completed installation should include the following: 

A.  Fireplace  items  shown  in  Figure  2  and  listed  in 
Table 1. 

B.  Damper (sold separately) (Shown in Figure 11). 

C.  Chimney Cap (sold separately) (Shown in Figure 
22). 

D.  Fireplace Grate (sold separately) (Shown in Fig-
ure 26). 

E.  Full firebrick (sold separately) 

F.  Stone  Age  Multi-Purpose  Ready-Mix  Cement 
(sold separately).   

The Stone Age Fireplace has been tested and listed in 
accordance with UL 127 and ULC S610 standards for 
indoor or outdoor use, and is listed by OMNI-Test La-
boratories,  Inc.  for  installation  and  operation  in  the 
United States and Canada as described in this manual. 

This fireplace is designed to supplement your current 
heating system.  It is not designed to be used as a pri-
mary heat source.  

Ensure  that  appropriate  building  permits  required  by 
local codes are obtained before installation in an exist-
ing home.

 

 

 

 

Ce manuel est disponible en français à 

www.stoneagemanufacturing.com

This manual is available in French at 

www.stoneagemanufacturing.com

.  

NA36IND 

Front View 

Side  

Cutaway 

View

Figure 1. NA36IND Fireplace Assembly 

     & Cutaway View 

Содержание NA36IND

Страница 1: ... kit with all components necessary to complete the installation The kit is con figured for a flue chimney but a special adapter is available for a metal chimney Component arrange ment some of which is optional is shown in Figure 2 Components are shown in Table 1 Specifications and installation dimensions are shown in Table 2 A completed installation should include the following A Fireplace items s...

Страница 2: ... when hearth is greater than 6 from floor A 12 Mantle 48 from hearth B Top Trim 36 from hearth C Side Trim 6 from fireplace opening D Front en closure Non combustible from hearth up 36 E 1 Combustible 36 from hearth E 2 E Hearth If the fireplace opening is 6 sq feet or larger the hearth shall extend at least 20 inches in front of the open ing and 12 inches beyond each side If the opening is less t...

Страница 3: ...t important that the Stone Age fireplace be installed according to the following instructions It is also important that local building codes be consulted and followed Improper installation could result in Overheating leading to fireplace failure Leakage of rainwater through and around the chimney Cracks and settling because of poor founda tions Emission of smoke sparks and gases into the living ar...

Страница 4: ... mortar for additional reinforcement if desired B When the base is level and square set the base plate 1 Level it from side to side and front to back See Figure 4 C Install the sidewall pieces 2 and the lower and middle back plates 3A 3B and 4A 4B Use 3 8 joint of mortar between each section Smooth out mortar and ensure sections remain level See Figures 5 and 6 D Lay a straightedge across the left...

Страница 5: ...k with the front lip resting on the front header 8 Mortar damper in place Ensure the damper opens and closes properly I Install the first complete ring of four interlocking throat components items 9 10 11 and 12 Check with a level See Figure 13 J Install second ring of four throat components Items 13 14 15 16 Check with a level See Figure 14 8 9 10 11 12 Figure 13 Lower Throat Level Figure 10 Fron...

Страница 6: ...g of clay liners and outer blocks or Stone Age Pipe Adapter if installing a metal pipe chimney See Figures 17 and 18 N If installing a mantel and side trim especially if it is wood or other combustible materials ensure the 13 14 16 15 17 18 19 20 21 22 23 Outer Block 23 Pipe Adapter 22 Clay Flue 22 21 21 Figure 18 Metal Pipe Chimney Figure 17 Stone Age Masonry Chimney Figure 14 Middle Throat Level...

Страница 7: ...pipe tested and certified to UL 103 standards for the US and ULC S604 standards for Canada 4 1 Stone Age Masonry System The Stone Age Masonry chimney system consists of stacking Stone Age chimney blocks and installing a clay flue inside A Place a clay flue inside the chimney block The holes in each corner of the chimney block allow the placement of rebar and mortar for additional rein forcement if...

Страница 8: ...provided by the chimney pipe manufacturer Install a Stone Age masonry pipe adapter sold sepa rately to the top of the firebox using a 14 I D adapt er for the NA 36 Connect the first pipe section to the metal adapter as shown in Figure 23 Chimney plumbing can either be straight through the ceiling and through the roof or if the fireplace is installed on an outside wall the chimney can be external t...

Страница 9: ...ections extending the chimney through the roof H A wood chase may be constructed around the exposed chimney for aesthetic effect Ensure the minimum recommended clearances to combustibles specified by the metal chimney pipe manufacturer are maintained inside the chase I Install roof flashing appropriate to the roof pitch and any other pipe accessories per the pipe manufac turer s instructions J Ins...

Страница 10: ...re nor mal H Do not alter this fireplace to the extent that it would jeopardize the structural integrity of the fire place Drilling or cutting a hole for a gas line fresh air vent or ash dump is acceptable Use only Stone Age authorized equipment with this fireplace 5 2 Selection of Wood Use cured wood logs only Scrap wood produces sparks Treated wood coal or woods dipped in pine tar should not be ...

Страница 11: ... the firebox and light it This will create an updraft and clear the flue of cold air The following steps are recommended when starting a fire A Remove any excess ash from the fireplace Ex cessive ash may reduce airflow Some owners prefer to leave a small layer to insulate the cold refractory brick below the grate helping fire starting B Open and close the damper to ensure it operates properly Leav...

Страница 12: ...air flows freely through it E Spot check the refractory bricks and mortar for small cracks It will expand slightly with the heat and then contract as it cools Replace refractory bricks when the cracks open more than or when pits become extensive and deeper than 3 16 or when any piece of refractory larger than 2 inches in diameter becomes dislodged F If creosote has accumulated it should be re move...

Страница 13: ...13 ...

Страница 14: ...cturing defects in the Stone Age product and does not cover de fects or faulty workmanship in the installation of the product or the ma sonry or other structure in which it is installed Also this warranty does not cover items that have been damaged due to over heating modifica tion improper storage or maintenance Stone Age shall repair or re place at its option any defective Stone Age product comp...

Отзывы: