Repairing the knitting machine
7
Needle selection displacement 7.6
354
7.6 Needle selection displacement
Condition:
Operating system of the knitting machine: Operating system OKC V 2.5
(or higher).
With this test the interaction of the impulse sensor, the control unit and the
different selection systems is synchronized. This takes place with the help
of test series. With different reaction times it is checked whether the needles
are driven out to the "stitch" position for knitting or not. You have to check
this in both carriage directions. You enter these test results in a table. From
these test results the optimum reaction time is calculated.
The needle selection displacement is carried out with the following steps:
Reset reference values of impulse sensor, carry out carriage reference
run [-> 356]
Determining the needle selection displacement manually [-> 357]
Time required
Manually:
If you carry out the test series manually, you will need
between 2 and 4 hours depending on the machine gauge.
Automatic:
The measuring system "JNA" (Setup-Needle-Selection) is
available at your agency or at Stoll. With this measuring
system the test series are carried out automatically. Time
required: 30 - 60 minutes.
"JNA" measuring system
With the "JNA" measuring system you will get instructions on
how to carry out a needle selection displacement.
You do not need to carry out the section "Determine manually
the needle selection displacement" of this instructions.
Содержание CMS ADF-3
Страница 1: ...Operating instructions Type Computer type Component type CMS ADF 3 681 OKC 000 001 ID 263 800 GB...
Страница 16: ...About this document 1 Warnings in the documentation 1 5 16...
Страница 232: ...Adjusting knitting machine 4 Defining user profile 4 6 232...
Страница 270: ...Setup Data 5 Setup1 Editing the setup file 5 5 270...
Страница 296: ...Maintenance of the knitting machine 6 Lubricate knitting machine 6 3 296...
Страница 364: ...Repairing the knitting machine 7 Entering the data of the needle selection displacement manually 7 7 364...
Страница 410: ...Software Installation and basic settings 8 Diagnose Control 8 5 410...
Страница 436: ...Machine Management Tools 10 Send email directly from the machine 10 4 436...
Страница 444: ...Key word directory 11 444...