8
U421-I2A & U431-I2A OPERATOR’S MANUAL
513713 REV.0
Section 2: Operation
MAINTENANCE
PA
R
TS
TROUBLESHOO
TING
OPERA
TION
INTRODUCTION
A. Empty the Freezing Cylinders
Turn o
ff
freezing cylinders.
A.1
Press the Clean buttons.
Make sure the display
shows that the mix pumps
are on
A.5
Optional: Fill the bucket with Stera Sheen
solution to make cleaning parts easier after
disassembly.
NOTE
The machine must be emptied,
disassembled, cleaned and sanitized
every 3 days or per local health code
requirements (whichever is sooner).
NOTE
Wire trays are located at the upper left and
right corners of the cab to store bag caps.
NOTE
Set up cab and hoses for rinse procedure.
1. Remove the bags from the cab
and store them in a cooler.
2. Remove the three plastic bins
from the cab.
3. Remove the drawers. To
remove a drawer, pull it
out. Tilt the drawer up to
disengage the front rollers.
Pull it further out then up to
disengage the rear rollers.
A.3
In the cab, lift the drawer latches
and pull out the drawers.
Disconnect the bag adapters
from the bags and place caps
on the bags
A.2
Fill a bucket with 2 gallons of cool
tap water and place the coiled
hoses with bag adapters into
the bucket.
A.4
Содержание U421 series
Страница 1: ...Model U421 U431 Operator s Manual 513713 Rev 0...
Страница 40: ...40 U421 I2A U431 I2A OPERATOR S MANUAL 513713 REV 0...
Страница 41: ...513713 REV 0 U421 I2A U431 I2A OPERATOR S MANUAL 41...
Страница 42: ...42 U421 I2A U431 I2A OPERATOR S MANUAL 513713 REV 0...
Страница 44: ......