34
U421-I2A & U431-I2A OPERATOR’S MANUAL
513713 REV.0
Section 4: Troubleshooting
MAINTENANCE
PA
R
TS
TROUBLESHOO
TING
OPERA
TION
INTRODUCTION
Error Code (E3)
Run Time
Water-Cooled Machines
Is the water or
glycol system
turned off?
Are the water or
glycol lines kinked
or damaged?
Yes
Yes
Turn the system on.
Is the problem
fixed?
No
No
No
Yes
Yes
Repair or replace the
lines.
Is the problem
fixed?
No
No
Yes
Yes
No
Does the error
occur after the first
freezing cycle?
Disassemble machine
and reassemble
following the steps in the
operators manual.
Is the problem
fixed?
Contact your authorized
Stoelting distributor for
further assistance
Continue normal operation.
• Lack of water/glycol
fl
ow.
• Excess air in the freezing cylinder
due to air in the mix bags.
• Pump turned o
ff
or not operating
• Improper adjustments to the
IntelliTec2™ control.
E3 Common Causes