14
O111-I2F Model Machines
C.
To remove a condenser filter, grasp the top and
pull off. Visually inspect the filter for dirt. If it is
dirty, shake or brush excess dirt off of it and wash
it in warm, soapy water. Once the filter is clean,
rinse it thoroughly in warm, clear water and shake
dry, taking care not to damage the it in any way.
NOTE
If the condenser is not kept clean, refrigeration ef-
ficiency will be lost.
4.4 PREVENTATIVE MAINTENANCE
It is recommended that a preventative maintenance
schedule be followed to keep the machine clean and
operating properly. The following steps are suggested as
a preventative maintenance guide.
The United States Department of Agriculture and the Food
and Drug Administration require that lubricants used in
food zones be certified for this use. Use lubricants only in
accordance with the manufacturer’s instructions.
A.
Daily checks
Check for any unusual noise or condition and
repair immediately.
B.
Monthly checks
Check the condenser filter for dirt and clean if
necessary.
C.
Quarterly Checks
Check drive belts for wear and tighten belts if
necessary.
4.5 EXTENDED STORAGE
Refer to the following steps for storage of the machine
over any long period of shutdown time:
A.
Thoroughly clean all parts that come in contact
with mix with warm detergent water. Rinse in clear
water and dry all parts. Do not sanitize.
NOTE
Do not let cleaning solution stand in the freezing
cylinder or hopper during the shutdown period.
B.
Remove, disassemble, and clean the front door,
and auger shaft. Leave disassembled during the
shutdown period.
C.
Place the auger flights and auger support bushing
in a plastic bag with a moist paper towel. This
prevents them from becoming brittle if exposed
to dry air over an extended period of time (over
30 days).
D.
For water-cooled machines that are left in unheated
buildings, or buildings subject to freezing, the water
must be shut off and disconnected. Disconnect
the water inlet fitting. The fitting is located at the
rear of the machine. Run the compressor for 2 - 3
minutes to open water valve (the front door must
be attached for the compressor to run). Blow
out all water through water inlet. Drain the water
supply line coming to the machine. Disconnect
the water outlet fitting.
E.
Press the Main Power On/Off button to turn the
machine off.
F.
Disconnect the machine from the source of
electrical supply.
Содержание O111-I2F
Страница 1: ...Model O111 I2F OPERATORS MANUAL Manual No 513686 Rev 1 ...
Страница 2: ......
Страница 6: ......
Страница 12: ...Operators Manual 513686 6 O111 I2F Model Machines ...
Страница 24: ...Operators Manual 513686 18 O111 I2F Model Machines ...
Страница 28: ...Operators Manual 513686 22 O111 I2F Model Machines ...