19   i-CON Calibration  (Page 1 of 2)

You will need a suitable container to collect the product or seed when calibrating, and an accurate set of 

scales which weighs in grams 

At the machine 

1.

Air Force Models only  

switch the fan OFF at the junction box  

2.  Position a suitable container to collect product whilst calibrating 

3.  Place a few kilograms of seed in the hopper

 At the ICON instrument  

1.  Switch the head unit ON via the left hand side push 

button – wait until the start-up routine has finished and 
displays the main “home screen”

2.   Scroll through to the Setup Menu and select the 

Applicator Icon 

3.  Adjust the implement width accordingly - refer to the 

RDS manual, page 25, section 3.3, Set Implement 
Width                                                                                                        

4.  Ensure the correct application rate is 

entered – select  and adjust accordingly,                                                                                              
refer to the RDS manual, page 21, section 3.1, Setting the Application Rate

5.  Ensure the feed roller setup is appropriate for the intended product or seed type, application rate and 

forward speed range for application 

6.  The instrument calculates the calibration factor from the working width, target application rate, and the 

metered weight delivered whilst calibrating. If however as a result of the calibration routine, you find that 
you cannot achieve your desired field speed, displayed in the top right corner of the screen, then               
re-configure the feed roll assembly and repeat the calibration procedure

7.  Prime the feed rollers with product by pressing and holding briefly the prime button on the junction box 

- this will ensure a higher initial calibration accuracy, empty the contents of the tray back into the hopper

8.  For an 

Auto Calibration 

from the Product Setup page, touch

9.  Touch             and enter the quantity that you wish to dispense for calibration purposes. You can enter    

the quantity in grams if preferred. The CAL factor will however, still be calculated in kg/rev

10. Touch on the screen page

11. After 

the key the motor runs at the calibration speed (calculated from the Simulated Forward 

Speed, Width, Application Rate and current calibration factor)

12. The dispensed weight (based on the current calibration factor) is displayed

13. Weigh the product dispensed and then enter the measured weight, and press 

14. A new calibration factor is then re-calculated and displayed

15. Your in field min and max speeds will be displayed as per the 

image to the right hand side.  If you find that you cannot achieve 
your desired field speed, then re-configure the feed roller assembly 
and repeat the calibration procedure   (see pages 17 and 18 for 
more details)

16. Touch           to save the new factor, it is advised to repeat the 

calibration 2 more times to ensure accuracy

Содержание i-CON 130

Страница 1: ...partslist Read carefully before installation and operation This document must not be copied duplicated or distributed without prior consent All and patent rights apply STOCKS AG LIMITED CROMWELL ROAD...

Страница 2: ...al 11 11 3 Storage 11 11 4 OPTIONAL Heavy Duty Waterproof Cover 11 11 5 Disposal 11 12 Machine Mounting 12 13 1 i CON Control system 13 13 2 Wiring Diagram 13 13 3 Electrical Connections 13 14 Machine...

Страница 3: ...plements such as power harrows seed drills planters and vineyard interrow equipment The operator alone bears the associated risk if used for unintended use Intended use also includes compliance with t...

Страница 4: ...ngdom by Statutory Instrument 2008 No 1597 The Supply of Machinery Safety Regulations 2008 as amended The following standards have been applied in the design and construction of this machine BS EN ISO...

Страница 5: ...gdom by Statutory Instrument 2008 No 1597 The Supply of Machinery Safety Regulations 2008 as amended The following standards have been applied in the design and construction of this machine BS EN ISO...

Страница 6: ...damage is caused by external forces operator error modifications Jet washed or if the machine has not been used for its intended use Contact the company whom you purchased the machine from in the eve...

Страница 7: ...ot affected when the machine is in use If in doubt contact the vehicle manufacturer for more information After working the machine ensure that any unused product is returned safely to its original pac...

Страница 8: ...tem immediately by pressing and holding down the left hand rubber end cap on the instrument control panel for approx 2 seconds then release to power off 2 Disconnect the power supply by unplugging the...

Страница 9: ...Check the feed block is configured correctly and free running before starting work Daily checks 1 Check the feed motor and 12v Fan Air Force machines are working correctly 2 Ensure feed outlets and a...

Страница 10: ...lt in serious injury WARNING Do Not Jet Wash This machine is not designed to withstand Jet Washing WARNING Danger moving parts Risk of serious injury whilst the machine is in operation WARNING Risk of...

Страница 11: ...Storage Disconnect the power supply by unplugging the power cable or removing the inline fuse from the power cable if storing the machine for long periods It is the responsibility of the operator to...

Страница 12: ...e base plate can be base or rear mount Ensure there is sufficient room to tip the hopper for emptying and ensure any potential trapping points are noted taking care not to trap hands or fingers NOTE f...

Страница 13: ...imum power Connect the positive wire fused to the positive terminal and negative earth connection to the negative terminal NOTE the disc should rotate in a clockwise direction when viewed from above W...

Страница 14: ...h so that the switch is out of work when the sprung is at rest To change over remove the PVC cover plate held in position with the retaining screw to access the wiring terminals Remove the 2 wires fro...

Страница 15: ...n Off and Alarm Hopper contents kg and Low Level Alarm Part and Full Job Totals for Area ha Product dispensed kg and hours worked Grand Total for Area ha Product kg and hours worked Other features inc...

Страница 16: ...s or applying large seeds or granules the machine is also supplied with 2 larger 8 section feed rollers and spacers to allow 1 or 2 to be fitted as required Photo showing a feed block assembly with 2...

Страница 17: ...5mm feed roller combinations 1 2 3 4 5 2 6 Feed rollers and spacer arrangement for 3 outlet machines and 2 outlet opera on 1 3mm White Spacer 2 Stainless Shim Washer 3 24mm Black Spacer 4 13mm White...

Страница 18: ...nt for 1 outlet machines ed with 2 feed rollers 1 24mm Black Spacer 2 Feed Roller A 3 Feed Roller B 1 2 1 3 Feed roller and spacer arrangement for 3 outlet machines for 2 outlet opera on 1 3mm White S...

Страница 19: ...ou cannot achieve your desired field speed displayed in the top right corner of the screen then re configure the feed roll assembly and repeat the calibration procedure 7 Prime the feed rollers with p...

Страница 20: ...Kilograms per Hectare or Seeds per Square Metre The standard default mode for the i CON is in Kgs Ha and you will have to reconfigure the display if you want to display Seeds per Square Metre You do n...

Страница 21: ...21 7 8a 8b 9 10a 10b 11 21 Rotor Meter i CON 65L 130L Partsdrawing 86 Air Force Control Please refer to pages 15 and 16 showing feed roller and spacers combinations 110...

Страница 22: ...Motor Guard 1 25 GA072 3A 3 Outlet Plate 1 Gravity machines only 25a GA074A 1 Outlet Plate not shown 27 GA017A Hopper Baffle Plate Assembly New one piece design 28 MM044C Metering Motor 1 29 GA108B Fe...

Страница 23: ...7 TJ255B GPS Receiver 1 98 FJ107F 7m Fused power Cable 1 not shown 99 TJ118C Instrument Connector Cable 1 not shown 100 TJ242A 6m Instrument Cable 1 not shown 109 TJ120 12v Fan Unit 1 Air Force models...

Отзывы: