background image

 13

13-1   i-CON Control system

All control system components integral to the applicator unit are factory fitted. 

The Instrument has a 4.3" Colour Touch Screen which has 4 basic menu keys  (see page 16)

Separate power cable and head unit leads interconnect the tractor and the Seed Applicator Unit.                              

The following components need to be installed during fitment  (packed in hopper from factory)  

 

i-Con Instrument; TJ117C 

 

Instrument cables; TJ118C and TJ242A  

 

Power Cables; FJ107E

 

GPS Receiver; TJ255B

 

Cut out Switch; TJ252

13-2   Wiring diagram 

13-3  Electrical Connections 

Power requirement is 12 volts with a minimum continuous 30amp supply.  Ensure the power supply cable is  
connected direct to the vehicle battery to ensure maximum power. Connect the positive wire (fused) to the  
positive (+) terminal and negative earth connection to the negative (-) terminal                                                

NOTE

  the disc should rotate in a clockwise direction when viewed from above.    

WARNING 

Failure to connect to the vehicle battery may result in control function problems and      

possible damage to the vehicle battery and charging system must be in good condition to achieve the best 
results. All cables and controls are fitted with matching plugs and sockets.   

 WARNING 

any modifications to the wiring, fuse holder or control system will invalidate any warranty 

claim and may effect the performance of the machine                                                                             

OPTIONAL

 6m Radar Cable TJ234

OPTIONAL

 Ground Speed Radar TJ233A

Cut Out Switch  

Feed 
Motor

Hopper Level 

Sensor

(not used)

12v Fan 

supply cable (Airforce 

7m Fused                 

Power Cable 

Junction 

Box 

TJ119D 

6m Instrument  

Cable TJ242A

i-Con                      

Instrument 

Instrument Connector 

Cable TJ118C

GPS Receiver  

Содержание i-CON 130

Страница 1: ...partslist Read carefully before installation and operation This document must not be copied duplicated or distributed without prior consent All and patent rights apply STOCKS AG LIMITED CROMWELL ROAD...

Страница 2: ...al 11 11 3 Storage 11 11 4 OPTIONAL Heavy Duty Waterproof Cover 11 11 5 Disposal 11 12 Machine Mounting 12 13 1 i CON Control system 13 13 2 Wiring Diagram 13 13 3 Electrical Connections 13 14 Machine...

Страница 3: ...plements such as power harrows seed drills planters and vineyard interrow equipment The operator alone bears the associated risk if used for unintended use Intended use also includes compliance with t...

Страница 4: ...ngdom by Statutory Instrument 2008 No 1597 The Supply of Machinery Safety Regulations 2008 as amended The following standards have been applied in the design and construction of this machine BS EN ISO...

Страница 5: ...gdom by Statutory Instrument 2008 No 1597 The Supply of Machinery Safety Regulations 2008 as amended The following standards have been applied in the design and construction of this machine BS EN ISO...

Страница 6: ...damage is caused by external forces operator error modifications Jet washed or if the machine has not been used for its intended use Contact the company whom you purchased the machine from in the eve...

Страница 7: ...ot affected when the machine is in use If in doubt contact the vehicle manufacturer for more information After working the machine ensure that any unused product is returned safely to its original pac...

Страница 8: ...tem immediately by pressing and holding down the left hand rubber end cap on the instrument control panel for approx 2 seconds then release to power off 2 Disconnect the power supply by unplugging the...

Страница 9: ...Check the feed block is configured correctly and free running before starting work Daily checks 1 Check the feed motor and 12v Fan Air Force machines are working correctly 2 Ensure feed outlets and a...

Страница 10: ...lt in serious injury WARNING Do Not Jet Wash This machine is not designed to withstand Jet Washing WARNING Danger moving parts Risk of serious injury whilst the machine is in operation WARNING Risk of...

Страница 11: ...Storage Disconnect the power supply by unplugging the power cable or removing the inline fuse from the power cable if storing the machine for long periods It is the responsibility of the operator to...

Страница 12: ...e base plate can be base or rear mount Ensure there is sufficient room to tip the hopper for emptying and ensure any potential trapping points are noted taking care not to trap hands or fingers NOTE f...

Страница 13: ...imum power Connect the positive wire fused to the positive terminal and negative earth connection to the negative terminal NOTE the disc should rotate in a clockwise direction when viewed from above W...

Страница 14: ...h so that the switch is out of work when the sprung is at rest To change over remove the PVC cover plate held in position with the retaining screw to access the wiring terminals Remove the 2 wires fro...

Страница 15: ...n Off and Alarm Hopper contents kg and Low Level Alarm Part and Full Job Totals for Area ha Product dispensed kg and hours worked Grand Total for Area ha Product kg and hours worked Other features inc...

Страница 16: ...s or applying large seeds or granules the machine is also supplied with 2 larger 8 section feed rollers and spacers to allow 1 or 2 to be fitted as required Photo showing a feed block assembly with 2...

Страница 17: ...5mm feed roller combinations 1 2 3 4 5 2 6 Feed rollers and spacer arrangement for 3 outlet machines and 2 outlet opera on 1 3mm White Spacer 2 Stainless Shim Washer 3 24mm Black Spacer 4 13mm White...

Страница 18: ...nt for 1 outlet machines ed with 2 feed rollers 1 24mm Black Spacer 2 Feed Roller A 3 Feed Roller B 1 2 1 3 Feed roller and spacer arrangement for 3 outlet machines for 2 outlet opera on 1 3mm White S...

Страница 19: ...ou cannot achieve your desired field speed displayed in the top right corner of the screen then re configure the feed roll assembly and repeat the calibration procedure 7 Prime the feed rollers with p...

Страница 20: ...Kilograms per Hectare or Seeds per Square Metre The standard default mode for the i CON is in Kgs Ha and you will have to reconfigure the display if you want to display Seeds per Square Metre You do n...

Страница 21: ...21 7 8a 8b 9 10a 10b 11 21 Rotor Meter i CON 65L 130L Partsdrawing 86 Air Force Control Please refer to pages 15 and 16 showing feed roller and spacers combinations 110...

Страница 22: ...Motor Guard 1 25 GA072 3A 3 Outlet Plate 1 Gravity machines only 25a GA074A 1 Outlet Plate not shown 27 GA017A Hopper Baffle Plate Assembly New one piece design 28 MM044C Metering Motor 1 29 GA108B Fe...

Страница 23: ...7 TJ255B GPS Receiver 1 98 FJ107F 7m Fused power Cable 1 not shown 99 TJ118C Instrument Connector Cable 1 not shown 100 TJ242A 6m Instrument Cable 1 not shown 109 TJ120 12v Fan Unit 1 Air Force models...

Отзывы: