xDS 5000 safety figures
Operating manual ASP 5001
ID 442181.07
WE KEEP THINGS MOVING
23
7
7
xDS 5000 safety figures
7.1
PFH and MTTF
Observe the breakdown according to the sizes and daily operating time in the following tables.
7.1.1
Size 0 to 2
16 hours of operation every day
Cycle time
PFH [1/h]
MTTF
d
[years]
DC = 60 %
DC = 90 %
DC = 60 %
DC = 90 %
1 minute
1,015
10
-8
7,164
10
-9
100
a)
a) MTTF
d
is reduced to 100 years according to DIN EN ISO 13849-1:2008-12.
100
a)
2 minutes
6,059
10
-9
4,554
10
-9
5 minutes
2,432
10
-9
1,824
10
-9
10 minutes
1,218
10
-9
9,123
10
-10
30 minutes
4,062
10
-10
3,042
10
-10
1 hour
2,032
10
-10
1,521
10
-10
2 hours
1,016
10
-10
7,605
10
-11
4 hours
5,080
10
-11
3,803
10
-11
8 hours
2,540
10
-11
1,901
10
-11
16 hours
1,270
10
-11
9,506
10
-12
1 day
8,467
10
-12
6,338
10
-12
2 days
4,234
10
-12
3,169
10
-12
5 days
1,693
10
-12
1,268
10
-12
1 week
1,210
10
-12
9,054
10
-13
2 weeks
6,048
10
-13
4,527
10
-13
1 month
2,784
10
-13
2,084
10
-13
6 months
4,639
10
-14
3,473
10
-14
12 months
2,320
10
-14
1,736
10
-14