ST62GP-EMU2 Emulator User Manual
5 - Emulator Features
43/57
The SPI data register operates at full speed even in Step mode. For example, if
you load the Data register in Step mode, the value will be output immediately
on the pin.
5.9
Using the trigger outputs
Two connectors for trigger output signals are available on the front panel of the
ST62GP-EMU2.
You can generate these signals using the Hardware Events/Trigger Menu in the
WGDB6 Debugger. Output OUT1 and OUT2 can be programmed in two ways:
•
Synchronization mode (see
Figure 19
) allows you to configure two
synchronization pulses (Trig1 and Trig2) for triggering external hardware. The
events can be defined by addresses or address ranges.
•
Timing measurement mode (see
Figure 20
) allows you to measure the time
elapsed during a subroutine for example, using an oscilloscope connected to
OUT1. In this case, output OUT2 is SET on a user-defined address (Trig1), and
RESET on another one (Trig2).
Figure 19: Synchronization Mode
OUT1
OUT2
Trigger Event: Trig1
Trigger Event: Trig2
44 / 58