20
AFTER SALES SUPPORT
1300 886 649
AUS
MODEL: STR-PGGC75 PRODUCT CODE: 10288 09/2019
Table 2
Regulated for
NATURAL GAS
ULPG
Injection
∅
(mm)
MJ/h
Gas
Pressure
Injection
∅
(mm)
MJ/h
Gas
Pressure
Auxiliary
0.85
3.6
1.0 kPa
0.53
3.5
2.75 kPa
Semirapid
1.16
6.5
0.72
6.6
Rapid
1.49
10.8
0.93
11.0
Wok
1.80
14.4
1.07
14.7
Total
41.8
42.4
• Reassemble all the burners carefully; in particular you should make sure
that the burner crown is correctly placed on the burner.
•
IMPORTANT:
The minimum flow adjustment process must be completed
before the appliance is next used.
Installation (Cont.)
Minimum flow adjustment for hob gas taps
IMPORTANT:
Before adjusting the minimum flow of the burners, make
sure all gas is switched off (and preferably disconnected from the
appliance) and the electrical power has been disconnected.
• Remove all the trivets, burner crowns and
caps, and knobs.
• Unscrew the screws of the panel, then
remove the panel.
• Install the burner cap, burner crown and
knob of the burner. Switch the burner on
and set the knob at the minimum position.
• Place a small-bladed screwdriver on the
screw to adjust the minimum flow (as
shown in Fig. 13).
• Unscrew the adjusting screw in order to
increase the gas flow, or tighten it in order
to decrease the gas flow.
• The correct adjustment is obtained when
the flame has a length of about 3–4 mm.
Fig. 13