background image

 

 

 

Engine

 

 

• 

Run unleaded gasoline with an octane rating of 86 or higher 
and 10% or less ethanol.

 

• 

Check engine oil level on  level ground daily

 

• 

Drain Honda engine’s oil by removing oil plug in figure 5.

 

• 

Change the oil within the first month or 10 hours, do not 
overfill unit.

 

• 

Regular oil changes are required every 6 months or 50 hours 
or sooner depending on conditions.

 

• 

10w30 is recommended

 

• 

Clean/replace the air filter every 3 months or 25 hours.

 

• 

See supplemental Engine manufacturer booklet for addi-
tional maintenance procedures and requirements

 

 

Grease Points

 

 

• 

Grease the 2 bearings on the cutting shaft every 50 
hours as shown in Figure 4.

 

• 

Grease single bearing on the engine shaft every 50 
hours as shown in Figure 5. 

 

 

Operation

 

 

Starting and Stopping the Engine

 

 

1.

 

Turn engine switch to “On” position

 

Содержание SuperSeeder 2400

Страница 1: ...SuperSeeder 2400 Operator s Manual...

Страница 2: ...and free of any defects Do not use this equipment if any guards or safety decals are not in place Perform an inspection of the unit before each use Ensure all fasteners are secure the tires are prope...

Страница 3: ...these safety labels Signal word definitions DANGER indicates an imminently hazardous situation which if not avoided WILL result in death or serious injury WARNING indicates a potentially hazardous si...

Страница 4: ...missions features a maintenance free design Belt Inspect the belts every 50 hours or annually for signs of wear Blade Belt Replacement Procedure 1 Put blade engagement level in off position up 2 Remov...

Страница 5: ...5 Figure 3 Figure 1 Figure 2...

Страница 6: ...ired every 6 months or 50 hours or sooner depending on conditions 10w30 is recommended Clean replace the air filter every 3 months or 25 hours See supplemental Engine manufacturer booklet for addi tio...

Страница 7: ...7 Figure 4 Figure 5...

Страница 8: ...gure 6 2 Rotate the handle forward until the blades touch the ground Push forward one additional notch to set proper depth for most applications and release lever 3 Raise the blades to transport the u...

Страница 9: ...9 Figure 6 Figure 7...

Страница 10: ...unit is equipped with a hydrostatic transmission bypass valve as shown in Figure 9 Engaging the bypass puts the transmission in neutral allowing the unit to roll easily Usage 1 Set desired cutting dep...

Страница 11: ...11 Figure 8 Figure 9 Figure 10...

Страница 12: ...www StingerEquipment com 2140 Spencer Court LaGrange KY 40031 502 536 0716...

Отзывы: