background image

©  stilum GmbH, Gewerbegebiet Larsheck, D-56271 Kleinmaischeid  •  Tel. +49 (0) 2689 92790-0  •  All rights and product modifications reserved

Mounting instructions merry-go-round „rotundo 5“ 

Item No. 51 4100 401

State: 04.06.2020 p. 3

 

5.  After a setting period of 10 – 14 days, depending on weather conditions and 

foundation size, fill up and compress the holes between the foundation and 

the foundation hole with excavation.

6.  Clean the foundation surface and place the play equipment on the foundation 

anchor and screw it down. 

7.  Cover the entire impact area with fall protection according to the required 

drop height in accordance with EN 1176-1.    

 

 

 

 

Critical drop height: 330 mm

 

Recommended surface material: grass, sand, wood chip, gravel, synth. im-
pact protection. 
With a smaller installation depth (special edition) we recommend synthetic 
impact protection. In this case, make sure that protruding parts (e.g. screws, 
gusset plates) are covered with appropriate fall protection.

8.  Do not allow children to use the equipment before the installation has been 

finished.  

 

Attention:

 If the play equipment has been incompletely installed or partly dis-

mantled when carrying out maintenance and repair work, this may lead to par-
ticular risks of injury for the user. For this reason, make clearly visible that the 
equipment shall not be used in such cases. 

NOTE:

 Play equipment, which contain components made of stainless steel 

should not come with „normal“ steel parts in contact. Those steel parts may rub 

off and leave small steel particles in combination with moisture brown rust stains.
If such corrosion occur on stainless steel parts, they are fine with an abrasive 

(240 grit) to remove.  
Please take care when transporting and setting up the fact that the components 
are made of stainless steel with no „normal“ steel parts in contact.

Diagram 3: Top view

Area of the 

minimum space

3250

1501

OHNE SCHRIFTLICHE ZUSTIMMUNG DER KAISER GMBH DARF DIESE 

TECHNISCHE UNTERLAGE WEDER VERVIELFÄLTIGT, NOCH DRITTEN MITGETEILT ODER 

ZUGÄNGLICH GEMACHT WERDEN, NOCH IN SONSTIGER WEISE MISSBRÄEUCHLICH VER- 

WENDET WERDEN. ZUWIDERHANDLUNGEN WERDEN URHEBERRECHTLICH VERFOLGT.

1

 

rotundo5

Benennung

Gepr.

Blatt

Datum

Projekt

Gez.

Zeichnungsnummer

Rev

Änderung

Datum

1:20

A3

Name

Name

Draufsicht

0211-00-00

Maßstab

Schramm

02.10.17

 

 

A  Fallraum kleiner

08.01.19 ES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gewerbegebiet Larsheck

56271 Kleinmaischeid

Deutschland

Отзывы: