background image

©  stilum GmbH, Gewerbegebiet Larsheck, 56271 Kleinmaischeid  •  Tel. +49 (0) 2689 92790-0  •  All rights and product modifications reserved.

Maintenance instructions for „Crosstrainer Stepper“ 

Item-No. 55 1012 401

State: 23.05.2016 p. 1

 

Attention!

 

The maintenance intervals mentioned above are to be understood as recommen-
dations. The frequency of inspections has to be increased accordingly in case of 
intensive use of the equipment, extreme weather conditions, installations near the 
coast or in places which are often subject to vandalism and depending on the age 
of the equipment! 
In addition to the maintenance recommendations given by the manufacturer, it is 
also absolutely necessary to follow the regulations stipulated in DIN EN 1176-7! 

 

When exchanging or repairing elements, please always use original spare parts 
for the sake of operational safety and for liability reasons! 
If the play equipment has been incompletely installed or partly dismantled when 
carrying out maintenance and repair work, this may lead to particular risks of 
injury for the user. For this reason, make clearly visible that the equipment shall 
not be used in such cases!

Quarterly operative inspection: 

1.  Check the play and safety area for obvious safety hazards and cleanliness 

(e.g. exposed foundations, missing or damaged parts, missing or insufficient 
impact absorption, broken pieces, dirt etc.).

2.  Check the play area for cleanliness and damages. Protruding elements, if 

there are any, have to be removed. If necessary fill up the installation depth 
to the mark „game level“. 

3.  Check the equipment for cleanliness, correct functioning, wear, stability and 

damages. Check all the fixing elements and retighten them if necessary. In 
case of damages, replace the damaged elements. 

Annual main inspection  
(in intervals of not more than 12 months):    

 

In addition to

 the checks of the operative inspection, pay special attention to the 

stability of the equipment (which may be affected due to corrosion or vandalism) 
and its operational safety, especially after repair works or after mounting new 
elements or replacing existing elements. For that purpose, it may be necessary to 
uncover the foundations.