background image

6 | 

P a g e

 

 

STEP 2.1 

WALL ASSEMBLY 

2.1 - ASSEMBLY PARTS 

 WALL ASSEMBLY 

PART CODE  QTY 

DESCRIPTION 

9P 

900mm Wall panel 

65HHS 

65mm Hex head screw 

 

2.1 - ASSEMBLY 

 WALL ASSEMBLY 

Screw through 9P into 9P (Top, centre & bottom) using 3 x 65HHS, holding studs flush on the 
inside. 

 

 

 

 

9P

 

 

Screw 3 x 65HHS 
(Top, centre & 
bottom) 

FRONT OF SHED 

9P

 

 

Содержание Windsor S3008

Страница 1: ... construct your shed is included inside the pack cedar panels doors windows hardware kits roof sheeting Please ensure you fully unpack all the parts check against the parts checklist before contacting customer service about anything you believe may be missing Thank you ...

Страница 2: ...der 12mm Drill bit 6mm Drill bit Phillips head drive Hex Head Drive 5 16 Safety glasses Gloves Before assembly Remove all parts from packages and place in a safe place close to assembly area Review all instructions continue to refer to instructions throughout assembly step by step Preparing your site Choose your site carefully site surface must be level unless an Elevation kit or Heavy duty floor ...

Страница 3: ...el 2 RS 880mm Sheeting 6 HK 4x6 Hardware Kit 1 RC 1200mm Ridge Cap 2 F 4ft Fascia Pack 1 CP Corner Post 1890x60x18mm 4 CS Cover Strip 1890x40x7mm 2 DS Door Step 840x42x19mm 1 DH Door Head 840x35x42mm 1 CT Collar Tie 480mm 1 IM 4x6 Instruction Manual 1 Floor Kit Option Floor Frame Rebated Floor 70x35mm Heavy Duty Floor 140x35mm Part Code Checked Part Description Qty EP End Plate 1800mm 2 DJ Double ...

Страница 4: ...OR FRAME Fasten through EP into DJ using 3 x 100BS per join 75N on Rebated Floor Fasten through EP into SJ using 2 x 100BS per join 75N on Rebated Floor HEAVY DUTY FLOOR KIT Heavy duty floor can be installed on unlevelled ground use supplied logs to level your floor by digging them into the ground Install heavy duty floor kit using L 4 logs 1 in each corner position shown above screw through frame...

Страница 5: ...ING INSTALLATION 1 1 FLOOR INSTALLATION PART CODE QTY DESCRIPTION FB 1 Floor Board 1713x800mm FB 1 Floor Board 1713x395mm 50PS 25 50mm Philips Screw 1 1 FLOOR SHEETS Fasten floor sheets to floor frame as shown below using 50PS ...

Страница 6: ...nel 65HHS 3 65mm Hex head screw 2 0 ASSEMBLY WALL ASSEMBLY Screw through FP into 9P top centre bottom using 3 x 65HHS Holding studs flush on the outside Note Ensure tongue on VJ cladding is facing upwards If optional window was purchased it can take the place of any 900mm 9P panel 9P Screw 3 x 65HHS Top centre bottom FP Cedar Strip ...

Страница 7: ...ASSEMBLY PART CODE QTY DESCRIPTION 9P 1 900mm Wall panel 65HHS 3 65mm Hex head screw 2 1 ASSEMBLY WALL ASSEMBLY Screw through 9P into 9P Top centre bottom using 3 x 65HHS holding studs flush on the inside 9P Screw 3 x 65HHS Top centre bottom FRONT OF SHED 9P ...

Страница 8: ...SEMBLY PART CODE QTY DESCRIPTION 12P 1 1200mm Wall panel 65HHS 3 65mm Hex head screw 2 2 ASSEMBLY WALL ASSEMBLY Screw through 12P into 9P Top centre bottom using 3 x 65HHS holding studs flush on the outside 12P Screw 3 x 65HHS Top centre bottom FRONT OF SHED 9P ...

Страница 9: ... WALL ASSEMBLY PART CODE QTY DESCRIPTION 9P 1 900mm Wall panel 65HHS 3 65mm Hex head screw 2 3 ASSEMBLY WALL ASSEMBLY Screw through 12P into 9P top centre bottom using 3 x 65HHS holding studs flush on the outside Screw 3 x 65HHS Top centre bottom 12P 9P ...

Страница 10: ...ASSEMBLY PART CODE QTY DESCRIPTION 9P 1 900mm Wall panel 65HHS 3 65mm Hex head screw 2 4 ASSEMBLY WALL ASSEMBLY Screw through 9P into 9P top centre bottom using 3 x 65HHS holding studs flush on the inside Screw 3 x 65HHS Top centre bottom FRONT OF SHED 9P 9P ...

Страница 11: ...LY PART CODE QTY DESCRIPTION FP 1 Front Wall panel 65HHS 3 65mm Hex head screw 2 5 ASSEMBLY WALL ASSEMBLY Screw through FP into 9P top centre bottom using 3 x 65HHS holding studs flush on the outside Screw 3 x 65HHS Top centre bottom FRONT OF SHED FP 9P Cedar Strip ...

Страница 12: ...LY PART CODE QTY DESCRIPTION BG 1 Back gable 65HHS 3 65mm Hex head screw 2 6 ASSEMBLY GABLE ASSEMBLY Carefully position BG in place inserting tongue on back panels into groove in BG Screw up through wall panels into bottom plate of gable using 3 x 65HHS at ends and centre ...

Страница 13: ...ront walls into groove in FG Screw up through wall panels into bottom plate of gable using 4 x 65HHS 2 each side STEP 3 0 ROOF ASSEMBLY 3 0 ASSEMBLY PARTS ROOF ASSEMBLY PART CODE QTY DESCRIPTION BB 1 Bottom batten TB 1 Top batten R 3 Roof rafter 100BS 6 100mm Batten screw 3 0 ASSEMBLY ROOF ASSEMBLY Slide rafters R into checked out sections in battens BB TB Fasten through BB and TB into R using 1 x...

Страница 14: ...Y ROOF ASSEMBLY Lay roof frame on a hard flat surface Position 1 roof sheet RS at each end of frame flush at top and flush with end of roof battens Fasten roof sheets to roof frame at each end in number sequence shown using 25RS in TB and 40RS into BB Note Only screw in pan at top and in rib at bottom BB TB Bent up edge at top Overhang 1 1 2 2 TOP TB BB Bent up Edge ...

Страница 15: ...T CODE QTY DESCRIPTION RS 1 Roof sheets 40RS 2 40mm roof screw 25RS 4 25mm roof screw 3 2 ASSEMBLY ROOF ASSEMBLY Fasten roof sheet RS to frame in sequence shown 1 x 25RS either side of join at top and 1 x 40RS through rib join at bottom TOP Bent up edge at top 1 1 2 3 2 3 ...

Страница 16: ...RIPTION 40RS 12 40mm roofing screw 25RS 12 25mm roof screw 3 3 ASSEMBLY ROOF ASSEMBLY Complete screwing off roof at top 1 x 25RS beside every rib Once top complete screw bottom off using 1 x 40RS in every rib Note use a straight edge to keep all screws in line and centre of the baton BB ...

Страница 17: ...RT CODE QTY DESCRIPTION C 1 2115mm Channel ST 4 Self tapping screw 3 4 ASSEMBLY ROOF ASSEMBLY Slide channel onto roof C Fasten channel 2115C to roof using ST x 4 in positions shown Repeat steps 3 0 to 3 4 for other roof panel 1 rib in Sheet join Sheet join 1 rib in TB BB ...

Страница 18: ...of rafters are flush with gables Fasten up through side wall top plates at each end and each panel join Ensure walls run parallel with bottom batten BB on roof Repeat this step for both roof panels STEP 3 6 COLLAR TIE INSTALLATION 3 6 ASSEMBLY COLLAR TIE INSTALLATION PART CODE QTY DESCRIPTION CT 1 Collar tie 65HHS 2 65mm Hex head screw 3 6 ASSEMBLY PARTS COLLAR TIE INSTALLATION Holding Collar tie ...

Страница 19: ... HS 6 Hinge Screw D 1 Door 3 7 ASSEMBLY DOOR HINGE ASSEMBLY Place door on back and hold hinge H in position Fasten hinges to door using 3 x hinge screws HS per hinge Position Hinges are to be placed at top and bottom of door They are to be centralised over bracing on back of door as per second and third image below ...

Страница 20: ...DOOR INSTALLATION PART CODE QTY DESCRIPTION D 1 Door HS 6 Hinge screw 3 8 ASSEMBLY DOOR INSTALLATION Hold door in position 3mm down from top Front of the door when closed will be flush with front of VJ cladding Screw through hinge into front wall as pictured ...

Страница 21: ...rom door edge Insert T handle in position and mark two outside holes Remove T handle and drill 2 x 6mm holes Insert T handle back in with bolts and fasten nuts on back of door STEP 4 0 DOOR HANDLE ASSEMBLY 4 0 ASSEMBLY PARTS DOOR HANDLE ASSEMBLY PART CODE QTY DESCRIPTION 1 T Handle Leaver 4 0 ASSEMBLY DOOR HANDLE ASSEMBLY Holding door in closed position flush with VJ cladding on front slide leaver...

Страница 22: ...s Nail door stop down using 2 x 40n if installing on a concrete slab use a small dynabolt to fix in place STEP 5 0 CORNER POST ASSEMBLY 5 0 ASSEMBLY PARTS CORNER POST ASSEMBLY PART CODE QTY DESCRIPTION CP 4 Corner post s 40N 24 40mm Nail 5 0 ASSEMBLY CORNER POST ASSEMBLY Hold corner post CP in position Fasten through corner post into wall stud using 6 x 40mm nail Spacing evenly up each corner post...

Страница 23: ...ARTS COVER STRIP ASSEMBLY PART CODE QTY DESCRIPTION CS 2 Cover strip 40N 12 40mm Nail 5 1 ASSEMBLY COVER STRIP ASSEMBLY Hold cover strips CS over join on wall panels Nail through cover strip into wall panels using 6 x 40mm nails 40N evenly spaced per strip ...

Страница 24: ...EMBLY 5 2 ASSEMBLY PARTS FASCIA ASSEMBLY PART CODE QTY DESCRIPTION F 4 Fascia 40N 8 40mm Nail 5 2 ASSEMBLY FASCIA ASSEMBLY Hold fascia s in position Flush with bottom of battens and meeting evenly at the top Nail into end of Battens ...

Страница 25: ...m Ridge Caps 40RS 4 40mm Roof screw 5 3 ASSEMBLY RIDGE CAP INSTALLATION Slide ridge caps into position Make sure peak of ridge cap is in line with peak of fascias Screw through ridge cap into 2nd rib in from end and through into batten Repeat this on both ends fasten through join both sides in center Screw here Screw here ...

Страница 26: ...ished installing your product PLEASE NOTE THAT IF YOU DO NOT COMPLETE THIS WARRANTY REGISTRATION FORM YOUR PRODUCT IS NOT COVERED BY WARRANTY PRODUCT MAINTENANCE We highly recommend you coat the external of your product with Intergrain Stain Light Oak This product cannot be bought off the shelf but is a known mix of Ultra Deck Intergrain Cedar Cypress and a black paint This can be purchased from D...

Страница 27: ...26 P a g e ...

Страница 28: ...ed in your backyard Please upload this image when completing the warranty registration Alternatively you can send the photos by email to sales stilla com au If you require any assistance please feel free to call or email Kind regards STILLA Customer Support 1800 784 552 sales stilla com au ...

Отзывы: