2
6159BA009 KN
1
► Pressurize the tank – move the unlocked
pump handle (1) up and down several times
until piston manometer (2) shows a pressure
of 2 bar (29 PSI).
The pressure in the tank must not drop any more
than 0.5 bar (7.25 PSI) within the next 30
minutes.
► Operate spray gun trigger – pressure must
escape.
► Release spray gun trigger – pressure must not
escape.
► Pull out piston manometer – pressure must
escape audibly.
► Completely depressurize the tank.
6
Filling the Container
The tank must not be under pressure.
► Unscrew the pump from the tank.
► Stand the tank securely on a level surface.
0000-GXX-0014-A0 KN
► Pour thoroughly mixed spray solution through
the opening (arrow) – do not exceed maximum
capacity (check max mark on scale).
► Screw the pump into the tank.
7
Spraying
7.1
Visual Inspection
Do not operate your unit if any of its components
are damaged. It is particularly important to check
the tank and hose connection for leaks.
7.2
Spraying
► Build up pressure – move the pump handle up
and down several times until the piston man‐
ometer shows the required working pressure –
see “Pressures / Spray Rates”
► Lock the pump handle.
Working pressures / spray rates – see "Specifi‐
cations".
English
6 Filling the Container
8
0458-583-0121-B