24
English
SE 121, SE 121 E
Wear parts
Some parts of the power tool are subject
to normal wear and tear even when the
machine is used for its intended
purpose. These parts must be replaced
in good time, depending on the nature
and duration of use.
Such parts include the following, for
example:
–
Filter element, filter bag
–
Carbon brushes
Fault:
Motor does not start
Fault:
Motor does not run in automatic
mode
Fault:
Reduced vacuuming
performance
Fault:
No suction when picking up
liquids
Cause
Remedy
Mains fuse
disconnected
Check and
reconnect mains
fuse
Overload
protection tripped
Leave vacuum to
cool for approx.
5 minutes
Cause
Remedy
Power tool
defective or not
plugged in
correctly
Check correct
operation of
power tool or plug
in correctly
Remedying faults
Cause
Remedy
Suction force
manually set to an
excessively low
level
See "Operation"
Filter bag full
See "Emptying
the container
Suction hose /
nozzle clogged
Clean suction
hose / nozzle
Filter element
soiled
See "Cleaning the
filter element" or
"Replacing the
filter element"
Seal between
upper part of
vacuum unit and
container soiled or
defective
Clean or replace
the seal
Cause
Remedy
Container is full
(float seals the
suction opening)
See "Emptying
the container"