EN
85
0478 131 8349 A - EN
Divided mowing area with a pond and a
free-standing tree
Docking station
:
Location (1) directly next to the house
A
No-go area
:
Installation around the free-standing tree,
based on a linking section installed at right
angles to the edge.
Pond
:
For safety reasons (specified wire
clearance), the perimeter wire (2) is routed
around the pond
B
.
Wire clearances
Clearance to the edge:
33 cm
Clearance to adjoining area that can be
travelled on (e.g. footpath) with a stepped
area height of less than +/- 1 cm:
0 cm
Around the tree:
33 cm
Clearance to the pond:
100 cm
Corridor
:
Installation of a corridor (3). Wire
clearance:
27 cm
Guide loops
:
Installation of two guide loops (4) for using
the offset drive home function.(
Minimum clearance from the corridor
entrance:
2 m
Note the minimum clearance to corners.
(
Programming
:
Define the total size of the mowing area,
program two starting points (5) (close to
the docking station and in the contorted
corner near the pond) (
Points to note
:
Unmown areas, e.g. around the pond must
be mown manually on a regular basis or
cut using a suitable lawn trimmer.