Sensor-Armatur für druckfeste (geschlossene) Warmwassergeräte | Sensor tap for 
pressurised (sealed unvented) DHW appliances| Robinetterie à capteur pour appareils 
de production ECS sous pression (en circuit fermé)| Sensorkraan voor drukvaste 
(gesloten) warmwatertoestellen

 

» WSH 10

 

» WSH 20

Содержание WSH 10

Страница 1: ...K EN INSTALLATIE Sensor Armatur f r druckfeste geschlossene Warmwasserger te Sensor tap for pressurised sealed unvented DHW appliances Robinetterie capteur pour appareils de production ECS sous pressi...

Страница 2: ...PERATION 1 General information 14 1 1 Safety instructions 14 1 2 Other symbols in this documentation 14 1 3 Units of measurement 14 2 Safety 14 2 1 Intended use 14 2 2 General safety instructions 14 3...

Страница 3: ...symbol f f Read these texts carefully Symbol Meaning Material losses appliance damage consequential losses and environmen tal pollution Appliance disposal f f This symbol indicates that you have to d...

Страница 4: ...7126 Water OFF D0000077127 4 Settings 4 1 Setting the temperature D0000077121 Your qualified contractor can set a fixed temperature or limit the setting range to prevent scalding 4 2 Touch settings Th...

Страница 5: ...y Factory setting distance 6 2 s 1x f f Touch the touch area for 2 sec onds The green LED lights up once 2x 2x 1x f f Touch the touch area briefly twice 0 5 seconds The green LED gives two short flash...

Страница 6: ...f f Touch the touch area briefly Setting continuous draw off in minutes Set continuous draw off from 0 5 to 20 minutes in increments of 0 5 minutes Factory setting approx 2 minutes 2 s 1x f f Touch th...

Страница 7: ...r to restore the factory settings Problem Cause Remedy Water does not run The sensor does not rec ognise black objects Select an object with a different colour The sensor is flashing The sensor is dir...

Страница 8: ...for special waste 5 3 Supplement Touch settings and programming on the internet Note You can also find separate instructions for Touch settings and programming for the sensor tap on the internet To v...

Страница 9: ...Instructions standards and regulations Note Observe all applicable national and regional regulations and instructions Note Water line pressures must be the same for domestic hot water and cold water 8...

Страница 10: ...or C Move your hand out of range of the sensor D Water runs for approx 4 seconds E Wait another 10 seconds The sensor tap is now ready for operation 12 Settings If required you can set a fixed tempera...

Страница 11: ...www stiebel eltron com WSH 10 WSH 20 43 NEDERLANDS NOTIZEN...

Страница 12: ...land STIEBEL ELTRON OY Kapinakuja 1 04600 M nts l Tel 020 720 9988 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 85107 57073 Metz C dex 3 Tel 0387 743...