INSTALLATION
Safety
www.stiebel-eltron.com
WPL ICS classic | WPL IKCS classic |
7
INSTALLATION
7. Safety
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
7.1 General safety instructions
We guarantee trouble-free function and operational reliability only
if original accessories and spare parts intended for the appliance
are used.
7.2 Instructions, standards and regulations
Note
Observe all applicable national and regional regulations
and instructions.
The tested appliance conforms to IEC 61000-3-12.
7.3 Operation of the appliance in buildings with
combustion equipment
As the appliance can produce negative pressure in the installa-
tion room, we recommend using a tightly sealing door between
the installation room and the living space containing combustion
equipment.
If, due to its use, the installation room is connected to the extract
air system, you must also make special arrangements for a supply
air vent in the installation room, to prevent any further increase in
the negative pressure in this room. The negative pressure created
by the appliance in the installation room is heavily influenced by
the pressure drop in the outdoor air line. For this reason, the
outdoor air line in particular should be as short as possible.
8. Appliance description
At +8 °C condenser temperature, the integral frost protection cir-
cuit automatically starts the heating circulation pump in the heat
pump circuit, thereby ensuring circulation in all water carrying
sections.
The heat pump starts automatically when the temperature in the
heat pump circuit drops below +5 °C.
8.1 Standard delivery
- Base unit
- Outside temperature sensor AF PT
- 2x Immersion/contact sensor TAF PT
- Transport aid
- 4x Sliding block
WPL 09 IKCS classic | WPL 17 IKCS classic
- 2 dummy covers
8.2 Required accessories
If installing a new appliance
- 2x air routing accessory LSWP 315 AWG Set
The air routing accessory is available in different lengths (0.7-4 m),
in silver (SR) or grey (GL), and as a version for light wells (L):
- LSWP 315-0.7 S AWG SR Set
- LSWP 315-2 S AWG SR Set
- LSWP 315-3 S AWG SR Set
- LSWP 315-4 S AWG SR set
- LSWP 315-0.7 S AWG GL Set
- LSWP 315-2 S AWG GL set
- LSWP 315-3 S AWG GL Set
- LSWP 315-4 S AWG GL Set
- LSWP 315-0.7 S AWG L Set
- LSWP 315-2 S AWG L Set
- LSWP 315-3 S AWG L set
- LSWP 315-4 S AWG L Set
If using existing air hoses and wall outlets AWG 315
- 2x quick-fit adaptor ZSA 315
8.3 Additional accessories
- Water softening fitting HZEA
- Condensate pump PK 10
- Internet Service Gateway ISG
- Remote control FET
- FE7 remote control
- TAF PT immersion/contact sensor
9. Preparation
9.1 Sound emissions
Take the following information into account when selecting the
installation location.
Note
The appliance is designed for indoor installation, except
in damp areas.
Note
For details regarding the sound power level, see chapter
"Specification / Data table".
- Never site the appliance on joist floors.
f
f
Ensure that the entire appliance frame is in full contact
with the substrate. Uneven substrates can increase sound
emissions.
f
f
Never install the appliance directly below or next to a living
room or bedroom.
f
f
Ensure that the air intake and discharge apertures in external
walls are not directed towards the neighbouring windows of
living rooms or bedrooms.