© 06184 som_6_si.monen.ind
d
5
|
SOM 6 SI
S1
S2
S4 / TRF
1.2.1 Allocation of clamps for system 1
Standard solar system
with 1 store, 1 pump and 3 sen-
sors. The sensor S4 / TRF can optionally be used for energy
production measurement.
R1
S3
Symbol
Specification
S1
Collector sensor
S2
Lower tank sensor
S3
Upper tank sensor
(optional)
S4 / TRF
Sensor for energy
production measurement
(optional)
R1
Solar pump