STIEBEL ELTRON SHZ 100 S GB Скачать руководство пользователя страница 3

www.stiebel-eltron.com 

SHZ S (GB) | 

3

SPECIAL INFORMATION | OPERATION 

 

General information

SPECIAL INFORMATION

 

- The appliance may be used by children aged 8 

and older and persons with reduced physical, 

sensory or mental capabilities or a lack of ex-

perience and know-how, provided that they are 

supervised or they have been instructed on how 

to use the appliance safely and have understood 

the resulting risks. Children must never play with 

the appliance. Children must never clean the ap-

pliance or perform user maintenance unless they 

are supervised.

 

- The connection to the power supply is only per-

missible as a permanent connection in conjunc-

tion with the removable cable grommet. Ensure 

the appliance can be separated from the power 

supply by an isolator that disconnects all poles 

with at least 3 mm contact separation.

 

- Observe the maximum permissible pressure (see 

chapter Installation / Specification / Data table).

 

- The appliance is pressurised. During the heat-up 

process, expansion water will drip from the safety 

valve.

 

- Regularly activate the safety valve to prevent 

it from becoming blocked, e.g. by limescale 

deposits.

 

- Drain the appliance as described in chap-

ter „Installation / Maintenance / Draining the 

appliance“.

 

- Install a type-tested safety valve in the cold water 

supply line. Please note that, depending on the 

static pressure, you may also need a pressure re-

ducing valve.

 

- Size the drain so that water can drain off unim-

peded when the safety valve is fully opened.

 

- Fit the discharge pipe of the safety valve with 

a constant downward slope and in a room free 

from the risk of frost.

 

- The safety valve discharge aperture must remain 

open to atmosphere.

OPERATION

1.  General information

The chapters “Special Information” and “Operation” are intended 

for both the user and qualified contractors.
The chapter "Installation" is intended for qualified contractors.

 

Note

Read these instructions carefully before using the appli-

ance and retain them for future reference.

Pass on the instructions to a new user if required.

1.1  Safety instructions

1.1.1  Structure of safety instructions

!

 

KEYWORD Type of risk

Here, possible consequences are listed that may result 

from failure to observe the safety instructions.

f

f

Steps to prevent the risk are listed.

1.1.2  Symbols, type of risk

Symbol

Type of risk

 

 

Injury 

 

 

 

Electrocution 

 

 

 

Burns 

(burns, scalding) 

1.1.3  Keywords

KEYWORD

Meaning

DANGER 

Failure to observe this information will result in serious 

injury or death.

WARNING 

Failure to observe this information may result in serious 

injury or death.

CAUTION 

Failure to observe this information may result in non-

serious or minor injury.

!

Содержание SHZ 100 S GB

Страница 1: ...OPERATION AND INSTALLATION Wall mounted DHW cylinder SHZ 30 S GB SHZ 50 S GB SHZ 100 S GB SHZ 150 S GB...

Страница 2: ...ounting bracket 6 9 3 Preparing the power cable 6 10 Installation 7 10 1 Appliance installation 7 10 2 Water connection and safety assembly 7 10 3 Power connection 7 10 4 Completing the installation 8...

Страница 3: ...iance Install a type tested safety valve in the cold water supply line Please note that depending on the static pressure you may also need a pressure re ducing valve Size the drain so that water can d...

Страница 4: ...ssure During the heat up pro cess expansion water will drip from the outlet side of the safety valve and or of the T P valve If water continues to drip when heating is completed please inform your qua...

Страница 5: ...peration with rapid heat up You can switch on rapid heat up with the corresponding key A remote control can also be installed for this purpose The rapid heat up function stops and will not restart whe...

Страница 6: ...sure various safety assemblies and pressure reducing valves are available These type tested safety assemblies protect the appliance against unacceptable excess pressure Pressure tested taps are availa...

Страница 7: ...uld not be used for other purposes No valve should be fitted between the expansion valve and the DHW cylinder f f To obtain a balanced water pressure in the cold water and DHW lines position the cold...

Страница 8: ...e discharge pipe of the safety assembly with a con stant slope Observe the information in the installation instructions of the safety assembly f f Turn the temperature selector to maximum f f Switch t...

Страница 9: ...WARNING Electrocution Before any work on the appliance disconnect all poles of the appliance from the power supply For some maintenance work you must remove the bottom cap If you also need to drain th...

Страница 10: ...Height mm 846 816 1126 1521 a20 Appliance Width mm 410 510 510 510 a30 Appliance Depth mm 420 510 510 510 b02 Cable entry I PG 21 PG 21 PG 21 PG 21 b03 Cable entry II PG 11 PG 11 PG 11 PG 11 c01 Cold...

Страница 11: ...rsion depth mm 380 380 350 380 16 4 Wiring diagrams and terminals 7 8 9 N L1 L2 L3 5 6 8 7 5 3 2 1 26_02_07_0348 4 6 9 1 Terminal for output changeover 2 Plug in distributor for N conductor 3 Heat con...

Страница 12: ..._02_07_0041 1 2 3 K1 Contactor 1 K2 Contactor 2 1 Power OFF contact 2 Off peak tariff meter 3 Peak tariff meter Single circuit operation 1 kW 7 8 9 1 N PE 230 V 2 kW 7 8 9 1 N PE 230 V D0000057900 3 k...

Страница 13: ...dish mm 22 28 35 Maximum permissible pressure drop expressed as a length of straight pipe i e no elbows or bends m 9 18 27 Pressure drop of each elbow or bend m 1 0 1 4 1 7 Connection dimensions Safet...

Страница 14: ...load 230 V kW 1 4 1 4 1 4 1 4 Rated voltage V 230 230 230 230 Phases 1 N PE 1 N PE 1 N PE 1 N PE Frequency Hz 50 50 50 50 Single circuit operating mode X X X X Dual circuit operating mode X X X X Man...

Страница 15: ...ose subsidiaries Such guarantee is only grant ed if the subsidiary has issued its own terms of guarantee No other guarantee will be granted We shall not provide any guarantee for appliances acquired i...

Страница 16: ...ja 1 04600 M nts l Tel 020 720 9988 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 85107 57073 Metz C dex 3 Tel 0387 7438 88 Fax 0387 7468 26 info stie...