12
| SHZ S (GB)
www.stiebel-eltron.com
INSTALLATION
Specification
Dual circuit operation with dual meter capture
1/3 kW
7 8 9
1/N/PE ~ 230 V
2/4 kW
7 8 9
1/N/PE ~ 230 V
PE
K1
K2
K2
K1
L1
L2
L3
N
N L1 L2 L3 5 6
85
�0
2�
07
�0
04
1
1
2
3
K1 Contactor 1
K2 Contactor 2
1 Power-OFF contact
2 Off-peak tariff meter
3 Peak tariff meter
Single circuit operation
1 kW
7 8 9
1/N/PE ~ 230 V
2 kW
7 8 9
1/N/PE ~ 230 V
D
00000
57
900
3 kW
7 8 9
1/N/PE ~ 230 V
4 kW
7 8 9
1/N/PE ~ 230 V
26
�0
2�
07
�0
17
5
Manual rapid heat-up operation
2 kW
7 8 9
1/N/PE ~ 230 V
26
�0
2�
07
�0
16
5
3 kW
7 8 9
1/N/PE ~ 230 V
26
�0
2�
07
�0
16
6
4 kW
7 8 9
1/N/PE ~ 230 V
85
�0
2�
07
�0
04
2