iNSTaLLaTiON
preparation
EN
GL
ISH
www.stiebel-eltron.com
SHF | SHS | SHL |
13
10.2 Standard delivery
The following are delivered with the appliance:
- Storage blocks
- 2 wall brackets only for SHS
10.3 Accessories
- 2-point room temperature controller (discharge controller)
- Booster heater
- DC Control Input assembly (DC control signal)
- Single-phase connection kit
- ZK dual circuit kit*
- Vario brackets
- Support bracket*
* Only for SHS
11. Preparation
Note
There must be continuous voltage at terminals L and N
on terminal strip X2.
Note
If the appliance is connected to an automatic charge
control system, the charge control system for electronic
charge controllers must be set without voltage correction.
11.1 Installation location
WARNING Burns
-
Ensure that the mounting wall is resistant to tem-
peratures up to at least 85 °C and the floor is resist-
ant to temperatures up to at least 80 °C.
-
Maintain the minimum clearances to adjacent ob-
jects.
Note
If the appliance is installed in rooms where flue gas, oil
or petrol vapours occur or where work involves solvents
and chemicals, the operation of the appliance can result
in long lasting odours or contamination of the appliance.
!
Material losses
The appliance must be installed flush against the wall.
11.2 Minimum clearances
≥100
≥500
≥100
≥100
D
00000
74
984
f
f
Ensure that the hot air can escape from the appliance with-
out obstruction.
12. Installation
12.1 Opening the appliance
D
00000
74
98
6
1
1 Air discharge grille
f
f
Undo the two quarter-turn locks on the air discharge grille
and remove it.
D
00000
75
74
0