STIEBEL ELTRON PSH 100 Universal EL Скачать руководство пользователя страница 5

Operation  

 

Appliance description

EN

GL

ISH

www.stiebel-eltron.com 

PSH Universal EL| 

25

3.  Appliance description

The appliance electrically heats up domestic hot water with the 

standard heating output or with rapid heating. The electronic 

control unit makes energy saving adjustments easier. Subject to 

the power supply and draw-off behaviour, the water is heated 

automatically to the set temperature.
The digital display provides you with information about the se-

lected set temperature and the enabled functions.
The inner cylinder is protected against corrosion by an enamel 

coating in conjunction with the integral protective magnesium 

anode.
The expansion water that collects as the water is heated up is 

drained off via the safety valve.
The thermal insulation is made of environmentally friendly and 

recyclable polyurethane foam.
The water heater is protected against frost, but the safety valve 

and water lines in the apartment or house are not. If the appliance 

is disconnected from the power supply, the water heater is not 

protected against frost. In such cases, if there is a risk of frost, the 

water heater must be drained.
The appliance can be operated in three ways: as a single circuit, 

dual circuit or manually.

Single circuit operation

In this operating mode, the appliance heats up the water automati-

cally with the standard heating output at any temperature setting. 

You can also start rapid heating.

Dual circuit operation

During off-peak tariff periods (cheap rate periods of power supply 

utilities), the appliance automatically heats up the water heater 

content with the standard heating output at any temperature set-

ting. You can also start rapid heating.

Manual operation

The appliance only heats the water when the rapid heating button 

is pressed. Once the maximum possible temperature has been 

reached, the appliance switches off and does not restart auto-

matically.

4.  Settings

4.1  Controls, display and symbols

1

2

3

26

�0

2�

07

�0

28

9

1

2

4

5

3

1  Plus button (increase of the displayed value)

2  Mode button (selection of the menu function)

3  OK button (confirmation of the displayed value)

4  Minus button (reduction of the displayed value)

5  Rapid heating button (switch on/off)
The set temperature is displayed.
If there is a fault, the display flashes.

Symbol

Description

Symbol

Description

 

ECO Comfort energy 

saving mode

 

Key lock 

 

ECO Plus energy saving 

mode

 

Frost protection 

 

ECO Dynamic energy 

saving mode

 

Rapid heating 

 

Temperature limit 

 

Heat-up 

During operation, the symbols for all enabled functions are il-

luminated.
When setting the menu functions, only the symbol for the current 

function and, if required, the heat-up symbol are displayed. The 

current setting of the function is displayed.
To save energy, the luminous intensity is reduced if you do not 

make any settings for approx. 5 minutes. As soon as you press a 

button, the display and symbols are illuminated again.

1

2

3

Содержание PSH 100 Universal EL

Страница 1: ...cher mit Elektronik Wall mounted water heater with PCB Ballon d ECS mural lectronique Warmwater wandboiler met elektronica N st nn z sobn k tepl vody s elektronikou N stenn akumula n ohrieva vody s el...

Страница 2: ...9 Preparations 30 9 1 Installation site 30 10 Preparing for installation 30 10 1 Preparing to install the appliance 30 10 2 Water connection 30 10 3 Electrical connection 31 11 Commissioning 32 11 1 C...

Страница 3: ...alve in the cold water supply line Please note that depending on the static pressure you may also need a pressure re ducing valve Size the drain so that water can drain off unim peded when the safety...

Страница 4: ...r materials Obser vation of these instructions and of instructions for any accessories used is also part of the correct use of this appliance 2 2 Safety instructions WARNING Burns During operation the...

Страница 5: ...output at any temperature setting You can also start rapid heating Dual circuit operation During off peak tariff periods cheap rate periods of power supply utilities the appliance automatically heats...

Страница 6: ...rost protection symbol appears Note If you change the set temperature the appliance switches automatically to ECO Comfort energy saving mode For low water consumption or very hard water we recommend a...

Страница 7: ...ny time between 61 C and 70 C This is also possible immediately after commissioning and after au tomatic reduction of the set temperature If you select a set tem perature higher than 70 C the set temp...

Страница 8: ...e to you at the end of the off peak time optimum standby energy consumption 4 4 6 Setting the temperature limit Note If you switch on the temperature limit in ECO Plus or ECO Dynamic energy saving mod...

Страница 9: ...by a heating contractor f f Have the protective magnesium anode checked by a heating contractor after the first year The heating contractor will then determine the intervals at which it must be check...

Страница 10: ...he dimensions for the holes to be drilled on the wall see chapter Specification Dimensions and connections f f Drill the holes if required and secure the wall mounting brackets with screws and rawl pl...

Страница 11: ...operation f f Pull out the cable grommet at the base while pressing the snap in tabs f f Push the cable grommet over the power cable and snap the cable grommet back in place Selecting the operating mo...

Страница 12: ...n f f Show the user the safety valve and its operating instructions and explain its significance f f Make the user aware of potential dangers especially the risk of scalding f f Hand over these instru...

Страница 13: ...off points 26_02_07_0288 1 1 Drain valve cap f f Undo the cap of the drain valve 14 3 Checking the protective anode f f Check the protective anode after the first year of use and re place if necessary...

Страница 14: ...X2 are inserted properly in both assemblies Check the assemblies and the connecting cable The water does not heat up The heat up symbol does not appear The display flashes E8 The high limit safety cu...

Страница 15: ...75 475 a30 Appliance Depth mm 392 392 492 492 492 492 b01 Entry electrical cables Height mm 98 5 98 5 78 5 78 5 78 5 78 5 c01 Cold water inlet Male thread G A G A G A G A G A G A Top clearance mm 20 2...

Страница 16: ...0 11 8 85_02_07_0023 4 1 Anode 2 Water heater 3 Mains terminal 4 Ceramic heating element in protective enamelled pipe 5 Heating output PSH 30 Universal EL 1 6 kW 230 V PSH 50 150 Universal EL 2 kW 230...

Страница 17: ...kW 2 6 2 6 3 3 L1 L3 N L2 PE 5 6 85_02_07_0021 1 1 Power OFF contact 16 2 2 Single circuit operation The output from rapid heating is shown after the forward slash PSH 30 Universal EL PSH 50 150 Univ...

Страница 18: ...2 911 6 683 7 009 12 650 19 898 20 082 Annual power consumption kWh 525 1287 1298 2518 4092 4099 Default temperature setting C 85 85 85 85 85 85 Sound power level dB A 15 15 15 15 15 15 Off peak peri...

Страница 19: ...h at 65 C horizontal kWh 0 75 1 05 1 07 1 36 1 31 1 55 Energy efficiency category B B B C C C Versions IP rating vertical IP25 IP25 IP25 IP25 IP25 IP25 IP rating horizontal IP24 IP24 IP24 IP24 IP24 IP...

Страница 20: ...STIEBEL ELTRON OY Kapinakuja 1 04600 M nts l Tel 020 720 9988 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 85107 57073 Metz C dex 3 Tel 0387 7438 88...

Отзывы: