14 

 

6.

 

ELCB checking 

 

Function: 

ELCB will cut out the Electric power system, when leakage is approximately 15 mA. 

- Disconnect Electric power lines as in the pictures.  

- Set Multi meter to Ohm range "Ω" or " 

)

)

)

) " and check as shown in the pictures. 

- Note the differences in the locations of the multimeter pointers . 

 

 

 

 

 

 

 

 

 

 

 

 

Check 

 

Meter Result 

 

Cause 

 

Action 

 

ON  

"Beep" signal " 

)

)

)

) "  

Pass  

No action  

No signal "OL" or (

 Ω) 

 

ELCB damaged 

 

Change new ELCB 

 

OFF  

"Beep" signal " 

)

)

)

) "  

ELCB damaged  

Change new ELCB  

No signal "OL" or (

 Ω) 

 

Pass 

 

No action 

 

 

 

ON Position

 

OFF Position

 

Содержание IM 45 EC

Страница 1: ...1 Service Manual IM_EC Author Mr Apiwat Limrueangwattanakul Date MAY 2015 Revision version 0...

Страница 2: ...nical data 5 Wiring Diagram 6 Troubleshooting 7 Root clause analysis 9 1 Heating Elements checking 9 2 TRIAC checking 10 3 Flow Switch checking 11 4 Control PCB checking 12 5 Thermostat checking 13 6...

Страница 3: ...3 Warning Warning This service manual is suitable for qualified Technicians only Warning Disconnect power supply before open cover...

Страница 4: ...trolled pressurized instantaneous water heater heats the water while it is flowing through the unit The heating power is switched on automatically in the event of the minimum flow rate being exceeded...

Страница 5: ...0 15 0 02 0 2 0 03 0 3 Max inlet water pressure MPa bar 1 10 Water connection G 1 2 Electrical connection 1 N PE 220 240V 220 V kW 4 5 6 0 8 0 230 V kW 4 9 6 6 8 7 240 V kW 5 4 7 1 9 5 Recommended cab...

Страница 6: ...6 Wiring Diagram Type DX E A Heating element B Electronic control set Phase Cut C ELCB D Triac Set E Thermal cut out TCO E B A D C...

Страница 7: ...ON and water not hot PCB failure Check PCB Missing water connection Check reed switch Reed switch failure Check Triac set Triac failure Problem Condition Cause Correction Reconnect inlet Power lamp ON...

Страница 8: ...water flow Breaker cut off Reed switch failure Water temperature not constant Change pump to smooth pressure type Check reed switch Irregular water flow Triac failure Check Triac set Water leak Wrong...

Страница 9: ...range or and check as show in the pictures Check Meter Result Cause Action Pole Pole Beep signal or 0 Element Pass No action No signal OL or Element Broken Change New Heater Pole GRD Beep signal or 0...

Страница 10: ...line H1 Heater GRD Ground Check Meter Result Cause Action L1 H1 Beep signal or 0 Triac short circuit Change new No signal OL or Triac Pass No action Check Meter Result Cause Action L1 GRD Beep signal...

Страница 11: ...d unplug reed switch from PCB then check it as show in the pictures Check Meter Result Cause Action Pole Pole No signal OL or Reed SW contact closed Change Reed SW Beep signal or 0 Pass No action Note...

Страница 12: ...12 4 PCB control Checking Visual check Check Result Cause Action Visual Electronic equipment burn PCB short circuit Change new one No visible damage PCB failure Change new one...

Страница 13: ...e thermostat follow the steps below Disconnect cables as in the picture Set multimeter to Ohm range or Check on poles Check Meter Result Cause Action Pole Pole Beep signal Pass No action No signal OL...

Страница 14: ...pictures Set Multi meter to Ohm range or and check as shown in the pictures Note the differences in the locations of the multimeter pointers Check Meter Result Cause Action ON Beep signal Pass No act...

Страница 15: ...er when the ELCB test button is pressed ELCB Test Press left rod ELCB Reset Press right rod ELCB ELCB Check Result Cause Action ELCB Test ELCB cut out power Pass No action ELCB not cut out power ELCB...

Страница 16: ...st station and turn the knob to the OFF position 2 Connect electricity wiring to the unit and connect the water valve then supply water to the system to check for leaks but keep the main breaker to th...

Отзывы: