3.4.2  Servo drives

Dimensions HUV 1 | 2

(33)*

(117)*

(86)*

(93)*

R65

(177)*

25

103

84

71

134

110

72

205

179

55

HUV 1 | HUV 2

HUV 65 | HUV 80

C2

6_

03_

01

_0

99

7

Dimensions HUV 65 | 80

45

193

160

98

150

D

00000

38

08

3

* Values in brackets are for HUV 1.

4.  Installation 

4.1  Installation position

The 3-way switching valves can be installed either vertically or 

horizontally. 

!

 

Beware of damage

The 3-way switching valves may not be installed sus-

pended, i.e. with the tappet facing down.

Permissible installation positions

90°

90°

C2

6_

03_

01

_0

99

8

4.2  Hydraulic connection

!

 

Beware of damage

The conditions in VDI 2035 regarding water quality must 

be complied with. So that the 3-way switching valve con-

trols the flow for a long time, we recommend the use of 

contamination filters.

!

 

Beware of damage

Make sure the ball is correctly positioned in 

the 3-way switching valve (note the mark on  

the spindle).

 

Note

As well as the flow direction A – AB and B – AB which 

is marked with an arrow on the housing, the opposite 

direction AB – A and AB – B is also permitted in STIEBEL 

ELTRON or Tecalor heat pump systems.

A

AB

B

A

AB

B

A

AB

B

A

AB

B

26

_0

3_

01

_0

99

9

Содержание HUV 1

Страница 1: ...d Installation Operating and installation Utilisation et Installation Gebruik en Installatie 3 Wege Umschaltventil 3 way switching valve Soupape d inversion 3 voies Drieweg omschakelklep HUV 1 HUV 2 H...

Страница 2: ...ong as it is used in the same way 2 2 Safety instructions Observe the following safety instructions and regula tions Heat pump systems and accessories may only be installed by a recognised specialised...

Страница 3: ...al The valve opens by turning clockwise and closes by turning anticlockwise factory setting HUV 65 HUV 80 only The lift drives are regulated by a 3 point control system and move the closing element wh...

Страница 4: ...he tappet facing down Permissible installation positions 90 90 C26_03_01_0998 4 2 Hydraulic connection Beware of damage The conditions in VDI 2035 regarding water quality must be complied with So that...

Страница 5: ...tion diagram open closed control a b 1 2 3 N L a a b b D0000043142 1 blue 2 brown 3 white 5 Maintenance The 3 way switching valves with integrated servo drive require no maintenance They do not contai...

Страница 6: ...ed II double insulated II double insulated IP rating IP54 IP54 IP54 IP54 Dimensions Length mm 84 5 131 5 290 310 Weights Weight kg 1 65 4 8 16 3 22 5 Values Permissible medium H2O H2O H2O H2O Permissi...

Страница 7: ...ssued by those subsidiaries Such warranties are only granted if the subsidiary has issued its own terms of warranty No other warranty will be granted We shall not provide any warranty for appliances a...

Страница 8: ...ergissingen en technische wijzigingen Salvo error o modificaci n t cnica R tt till misstag och tekniska ndringar f rbeh lls Excepto erro ou altera o t cnica Zastrze one zmiany techniczne i ewentualne...

Отзывы: